ds1859 Maxim Integrated Products, Inc., ds1859 Datasheet - Page 17
ds1859
Manufacturer Part Number
ds1859
Description
Ds1859 Dual, Temperature-controlled Resistors With Internally Calibrated Monitors
Manufacturer
Maxim Integrated Products, Inc.
Datasheet
1.DS1859.pdf
(28 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ds1859B
Manufacturer:
NA
Quantity:
20 000
Company:
Part Number:
ds1859B-020
Manufacturer:
Maxim Integrated
Quantity:
10 000
Company:
Part Number:
ds1859B-020+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Company:
Part Number:
ds1859B-020+T&R
Manufacturer:
Maxim Integrated
Quantity:
10 000
Company:
Part Number:
ds1859B-050
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
ds1859B-050
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
ds1859B-050+
Manufacturer:
Maxim
Quantity:
49
Company:
Part Number:
ds1859B-050+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
ds1859E+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
ds1859E-020+
Manufacturer:
DALLAS
Quantity:
20 000
Company:
Part Number:
ds1859E-020+T&R
Manufacturer:
UNIBRAIN
Quantity:
2 400
Part Number:
ds1859E-020+T&R
Manufacturer:
DALLAS
Quantity:
20 000
Company:
Part Number:
ds1859E-050+
Manufacturer:
MAXIM
Quantity:
8 720
Company:
Part Number:
ds1859E-050+
Manufacturer:
Maxim Integrated Products
Quantity:
1 919
Main Device (continued)
LOCATION
MEMORY
72 to 73
(hex)
Bit 7
74
3
2
1
0
6
5
4
3
2
1
0
Dual, Temperature-Controlled Resistors with
EEPROM/
SRAM
SRAM
SRAM
—
—
—
—
—
—
—
—
—
—
—
—
R/W
—
—
—
—
—
—
—
—
—
—
—
—
—
R
____________________________________________________________________
DEFAULT
SETTING
(hex)
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Internally Calibrated Monitors
NAME OF LOCATION
Warning flags
Reserved
MON1hi
MON1lo
MON2hi
MON2lo
TMPhi
TMPlo
V
V
MINT
CC
CC
X
X
X
hi
lo
A mask of all flags located in Table 01 byte
88h determines the value of MINT. MINT is
maskable to 0 if no interrupt is desired by
setting Table 01 byte 88h to 0.
This warning flag goes high when the upper
limit of the temperature setting is violated.
This warning flag goes high when the lower
limit of the temperature setting is violated.
This warning flag goes high when the upper
limit of the V
This warning flag goes high when the lower
limit of the V
This warning flag goes high when the upper
limit of the MON1 setting is violated.
This warning flag goes high when the lower
limit of the MON1 setting is violated.
This warning flag goes high when the upper
limit of the MON2 setting is violated.
This warning flag goes high when the lower
limit of the MON2 setting is violated.
CC
CC
setting is violated.
setting is violated.
FUNCTION
—
—
—
—
—
17