ds26518 Maxim Integrated Products, Inc., ds26518 Datasheet - Page 155

no-image

ds26518

Manufacturer Part Number
ds26518
Description
8-port T1/e1/j1 Transceiver
Manufacturer
Maxim Integrated Products, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS26518
Manufacturer:
DS
Quantity:
5 653
Part Number:
DS26518
Manufacturer:
DS
Quantity:
6 203
Part Number:
DS26518
Manufacturer:
DS
Quantity:
1 045
Part Number:
DS26518
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
ds26518-N
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
ds26518GN
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
ds26518GN+
Manufacturer:
Maxim Integrated Products
Quantity:
135
Part Number:
ds26518GN+
Manufacturer:
TI
Quantity:
518
Part Number:
ds26518GN+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
ds26518GN+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
ds26518GN+
Quantity:
347
Part Number:
ds26518GNB1
Manufacturer:
Maxim Integrated
Quantity:
10 000
Company:
Part Number:
ds26518GNB1
Quantity:
1 228
Company:
Part Number:
ds26518GNB1
Quantity:
1 228
Part Number:
ds26518GNB1+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
ds26518NB1+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Note: This register has an alternate definition for T1 mode. See RCR1.
Bit 6: Receive HDB3 Enable (RHDB3)
Bit 5: Receive Signaling Mode Select (RSIGM)
Bit 4: Receive G.802 Enable (RG802). See
Bit 3: Receive CRC-4 Enable (RCRC4)
Bit 2: Frame Resync Criteria (FRC)
Bit 1: Sync Enable (SYNCE)
Bit 0: Resynchronize (RESYNC). When toggled from low to high, a resynchronization of the receive-side framer is
initiated. Must be cleared and set again for a subsequent resync.
0 = HDB3 disabled.
1 = HDB3 enabled (decoded per O.162).
0 = CAS signaling mode.
1 = CCS signaling mode.
0 = Do not force RCHBLKn high during bit 1 of time slot 26.
1 = Force RCHBLKn high during bit 1 of time slot 26.
0 = CRC-4 disabled.
1 = CRC-4 enabled.
0 = Resync if FAS received in error three consecutive times.
1 = Resync if FAS or bit 2 of non-FAS is received in error three consecutive times.
0 = Auto resync enabled.
1 = Auto resync disabled.
7
0
RCR1 (E1 Mode)
Receive Control Register 1
081h + (200h x (n - 1)) : where n = 1 to 8
RHDB3
6
0
RSIGM
5
0
Figure 11-30
155 of 286
RG802
4
0
for details.
RCRC4
3
0
DS26518 8-Port T1/E1/J1 Transceiver
FRC
2
0
SYNCE
1
0
RESYNC
0
0

Related parts for ds26518