dms-ps-cm Murata Manufacturing Co., Ltd, dms-ps-cm Datasheet - Page 3

no-image

dms-ps-cm

Manufacturer Part Number
dms-ps-cm
Description
High Ef?ciency, Ac/dc Instrumentation Power Supplies With Individually Isolated Outputs
Manufacturer
Murata Manufacturing Co., Ltd
Datasheet
1. Shock Hazard: DMS-PS-CM Series power supplies feature touch-proof
2. AC Supply Fuse (F1): All DMS-PS-CM Series power supplies are equipped
terminals blocks and fully-isolated plastic construction, thereby greatly reduc-
ing the risk of electrical shock. However, these are mains-powered devices
whose operation is derived from hazardous and potentially lethal voltages.
All service and installation must be performed by qualified personnel, with
the ac supply voltage de-energized. Before making connections to any of
the unit’s terminal blocks, use a digital voltmeter to verify that the ac supply is
de-energized (off).
with a built-in 1A/250V time-lag fuse. Replacement fuses must be of the
same type and rating; please refer to the Functional Specifications section
of this datasheet for more information. F1 is conservatively rated in order
to reduce nuisance tripping which might occur during power-up or output
overload conditions. However, F1 is primarily intended to provide protection in
the event of catastrophic failure in the DMS-PS-CM’s ac/dc converter.
Warnings (Marking)
TECHNICAL NOTES
Ordering Information and Selection Guide
MPS Part No.
DMS-PS1-CM
DMS-PS2-CM
DMS-PS3-CM
DMS-PS4-CM
DMS-PS5-CM
DMS-PS6-CM
DMS-PS7-CM
DMS-PS8-CM
DMS-PS9-CM
DMS-PS10-CM
IMPORTANT! To ensure safe and reliable operation, DMS-PS-CM
power supplies must be installed and serviced by qualified
personnel. Contact Murata Power Solutions if there is any doubt
regarding their installation and/or operation. Please read all of the
following technical and application notes BEFORE installing or
making connections to DMS-PS-CM power supplies.
Efficiency typical @120V/60Hz
Caution, unit may become hot in normal operation, thereby creat-
ing a potential burn hazard. Disconnect ac mains and then allow
unit to cool before servicing.
Reference document: IEC 417, No. 5041.
Dangerous, potentially lethal voltages are present during normal
operation. Disconnect ac mains before servicing.
Reference document: IEC 417, No. 5036.
Caution, refer to accompanying documents for more informa-
tion. Reference document: ISO 3864, No. B.3.1.
Rated Power
10 Watts
10 Watts
10 Watts
16 Watts
16 Watts
16 Watts
16 Watts
5 Watts
5 Watts
5 Watts
www.murata-ps.com
Efficiency
75%
73%
71%
80%
75%
73%
82%
76%
74%
82%
24Vdc/0.45A
24Vdc/0.35A
24Vdc/0.30A
24Vdc/0.70A
24Vdc/0.60A
24Vdc/0.55A
12Vdc/1.35A
5Vdc/0.65A
5Vdc/0.35A
V1 Output
5Vdc/1A
High Efficiency, AC/DC Instrumentation Power
3. Fuse Replacement: If any dc-output drops to zero volts, and no fault
4. Wire Gauges and Fusing: All wiring connected to the DMS-PS-CM’s
Supplies with Individually Isolated Outputs
conditions exist within the external load circuitry or the ac mains, F1 may
have failed. F1 is located on the circuit (etch) side of the pc-board. Fuse
replacement is performed by first de-energizing and then disconnecting
the ac mains from TB4. Next, disconnect all load wiring from TB1, TB2,
and TB3. Lastly, remove the four screws that secure the pc-board to the
plastic case. After making sure that the new fuse is securely attached to its
mounting clips, re-assemble the unit using all four screws. Reconnect all
input and output wiring and re-apply ac power.
If the unit still does not operate properly, and the ac supply at TB4 is
measured to be within its specified operating range, the power supply
is defective and must be replaced. Except for F1, DMS-PS-CM supplies
contain no other user-serviceable components.
terminal blocks must meet the requirements specified in the Functional
Specifications section. All ac supply and load wiring must be rated for the
voltages and currents they will conduct and must comply with any code
or application-mandated requirements pertaining to the user’s specific
installation. Applications subject to vibration should include adequate strain
reliefs on both input and output wiring. Install the strain reliefs within 2-3
inches (5-7.5cm) of the terminal blocks.
It is recommended that all wiring be rated for 600V and 105°C operation
(UL1015 type, for example). Also, wire insulation must be stripped to within
±10% of the dimensions shown in Figure 2. All wires must be inserted
into their respective terminal blocks such that the screw terminal does not
pinch their insulation. No more than two wires should be connected to
any single terminal on TB1 through TB4. If two wires are attached to a
single terminal, be sure to use only two 20AWG (0.5mm
TB2, and TB3, and only two 18 or 20AWG (0.75 or 0.5mm
4.85Vdc/0.2A
4.85Vdc/0.2A
4.85Vdc/0.2A
4.85Vdc/0.2A
4.85Vdc/0.2A
4.85Vdc/0.2A
V2 Output
Technical enquiries email: sales@murata-ps.com, tel:
Figure 2. Insulation Strip Length
(6.4mm)
DMS-PS-CM Series
0.25"
4.85Vdc/0.2A
4.85Vdc/0.2A
4.85Vdc/0.2A
V3 Output
MPM_DMS-PS-CM.B02 Page 3 of 8
2
) wires on TB1,
2
) wires on TB4.
+1 508 339 3000

Related parts for dms-ps-cm