dms-eb-rms Murata Manufacturing Co., Ltd, dms-eb-rms Datasheet

no-image

dms-eb-rms

Manufacturer Part Number
dms-eb-rms
Description
Ac-to-rms Converter Application Board For Dms-30pc/lcd Meters
Manufacturer
Murata Manufacturing Co., Ltd
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
dms-eb-rms-C
Manufacturer:
Murata Power Solutions Inc
Quantity:
135
FEATURES
Displays true rms values of ac inputs
±0.5% accuracy for DMS-30PC-0 or DMS-
30LCD-0-5
±2% accuracy for DMS-30PC-1 or DMS-
30LCD-1-5
Also works with DMS-40PC/LCD meters (see Ap
Note 11)
www.murata-ps.com/rohs
For full details go to
(–) INPUT LO
(+) INPUT HI
 
REF. OUT
REF. IN
12
11
10
9
8
7
SG4
5
6
7
8
PRODUCT OVERVIEW
5V-powered DMS-30PC/LCD digital voltmeters. The meter/board combination has an input range of
0-750Vac with ±2V meters (1Vac resolution) or 0-199.9Vac with ±200mV meters (0.1Vac resolution).
A built-in screw-terminal block reliably interfaces signal and power connections. The DMS-EB-RMS
now accommodates user-installed modifications such as input-scaling resistors and isolated +5V dc/dc
converters.
cally isolated from its 5V supply (AC LOW is connected directly to 5V RETURN). When measuring any
input signal which is derived from ac power mains, a dedicated (i.e., it only powers the DMS-EB-RMS),
transformer-isolated +5V supply, with a minimum 1kV breakdown rating, must be used to power the
DMS-EB-RMS board/meter combination. When measuring ac power mains inputs, never connect the
DMS-EB-RMS’s 5V RETURN to chassis/earth ground anywhere in the system. Failing to follow these
instructions could defeat any safety grounding and will place the system +5V power supply, and all its
associated circuitry, at dangerously elevated ac-line potentials. In many applications, the MS-EB-RMS
installation is required to meet electrical code requirements. To ensure safe operation, the DMS-EB-
RMS board should only be installed and serviced by technically qualified personnel. See DMS
Application Note 11 for more details.
TB1
www.murata-ps.com
CAV
OUT
+V
COM
AC HI
S
Description: The DMS-EB-RMS board allows the true rms value of ac signals to be displayed on
Power and Safety Precautions: The DMS-EB-RMS’s AC HI and AC LOW inputs are not electri-
C1 100μF
+
Figure 1. DMS-EB-RMS Schematic Diagram
1
10μF
AC-to-RMS Converter Application Board for DMS-30PC/LCD Meters
C2
U1
J1
+
988k
AC LOW
R1
–V
V
CC
CF
IN
S
JP1
3
4
3
2
1
988k
R2
+5V
5
1.98k
R3
C4
2.2μF
6
5V Return
+
1
GND 2
V
5
6
7
8
IN
J4
U3
V
V
LV
OSC
V+
OUT
OUT
3
U2
2
1
BOOST
CAP+
CAP–
+V
–V
GND
Technical enquiries email: sales@murata-ps.com, tel:
DC/DC
J5
PS1
4
3
2
1
J6
–V
+V
OUT
Note: Components are user-supplied
and not part of the standard product.
IN
+
4
3
C5
2.2μF
SG1
SG2
SG3
DMS-EB-RMS
1
2
3
4
5
6
MPM_DMS-EB-RMS.B01 Page 1 of 2
+5V SUPPLY
5V RETURN
DP3
DP2
DP1
+1 508 339 3000

Related parts for dms-eb-rms

dms-eb-rms Summary of contents

Page 1

... Power and Safety Precautions: The DMS-EB-RMS’ and AC LOW inputs are not electri- cally isolated from its 5V supply (AC LOW is connected directly to 5V RETURN). When measuring any input signal which is derived from ac power mains, a dedicated (i.e., it only powers the DMS-EB-RMS), transformer-isolated +5V supply, with a minimum 1kV breakdown rating, must be used to power the DMS-EB-RMS board/meter combination. When measuring ac power mains inputs, never connect the DMS-EB-RMS’ ...

Page 2

... Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com Technical enquiries email: sales@murata-ps.com, tel: MPM_DMS-EB-RMS.B01 Page 508 339 3000 ...