MASWSS0100 Tyco Electronics, MASWSS0100 Datasheet - Page 2

no-image

MASWSS0100

Manufacturer Part Number
MASWSS0100
Description
GaAs SP3T 2.5 V High Power Switch
Manufacturer
Tyco Electronics
Datasheet
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
GaAs SP3T 2.5 V High Power Switch
0.1 - 3.0 GHz
Electrical Specifications: T
4. External DC blocking capacitors are required on all RF ports.
5. Insertion loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 MHz - 1 GHz, 39 pF for 0.5 - 3 GHz.
Functional Diagram
Insertion Loss
Control Current
2
Parameter
3
Return Loss
nd
rd
Trise, Tfall
Transients
Ton, Toff
Isolation
Harmonic
P.1dB
Harmonic
5
A
10% to 90% RF, 90% to 10% RF
= 25°C, V
1.0 GHz, P
1.0 GHz, P
50% control to 90% RF
50% control to 10% RF
Test Conditions
0.5 - 1.0 GHz
1.0 - 2.0 GHz
0.5 - 1.0 GHz
1.0 - 2.0 GHz
0.5 - 2.5 GHz
In Band
2.5 V
C
IN
IN
= +34 dBm
= +34 dBm
= 0 V / 2.5 V, Z
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
6. State 0 = -5 V to +2.5 V, State 1 = -2.5 V to +5 V.
7. Differential voltage, V (state 1) - V (state 0), must be 2.5 V
Truth Table
Qualification
Qualified to M/A-COM specification REL-201,
Process Flow –2.
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
V1
minimum.
1
0
0
0
= 50 Ω
V2
0
1
0
Units
dBm
dBc
dBc
mV
dB
dB
dB
dB
dB
nS
nS
µA
6,7
4
V3
0
0
1
Min.
23
RFC–
RF1
On
Off
Off
Typ.
MASWSS0100
0.5
0.6
-80
-70
25
20
20
38
83
94
58
50
RFC-
RF2
Off
On
Off
Max.
0.65
RFC -
-65
80
RF3
Off
Off
On
V2

Related parts for MASWSS0100