NET2-4231 Power-One, NET2-4231 Datasheet - Page 3

no-image

NET2-4231

Manufacturer Part Number
NET2-4231
Description
NET2 AC-DC Series
Manufacturer
Power-One
Datasheet
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic Interference
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
Ground Leakage
Environmental Specifications
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
Mechanical
DESCRIPTION
Metric Mounting
Chassis Size
APR 19, 2005 revised to JUN 28, 2006
CONDITIONS/DESCRIPTION
UL60950.
CSA 22.2, NO. 60950-00 (cUL).
EN60950-1 (TÜV).
IEC60950-1
Input to output per EN60950.
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
Per EN61000-4-2, level 4. Contact discharge: ±10%
Per EN61000-4-3, level 3. Frequency 0.8 - 1.0 GHz, 80% AM @ 1 kHz
Per EN61000-4-4, level 3.
Per EN61000-4-5, class 3.
UL60950/EN60950/CSA 6950-00
CONDITIONS/DESCRIPTION
Operating.
Non-Operating.
From 50°C to 70°C derate each output and total power
to 50% of rating at 70°C.
0°C to 70°C (after 15-minute warmup).
Non-Condensing.
Operating: Half-sine, 10 ± 3ms duration; one positive and
one negative shock in each of the three perpendicular axes
for a total of 6 shocks.
Non-Operating: Half-sine, 10 ± 3ms duration; one positive
AND
axes for a total of 6 shocks.
Operating: Logarithmic sweep, 1 octave/min 5-2000-5 Hz
vertical, lateral, and longitudinal axes;
5-32 Hz, 0.02” double amplitude;
32-2000 Hz
2000-32 Hz
32-5 Hz double amplitude.
Non-Operating: Random 1 hour/axis, vertical, lateral, and
max longitudinal over 10-2000 Hz.
NOTES
M3 x 0.5 mounting inserts: 3 mounting surfaces
one negative shock in each of the three perpendicular
Air discharge:
Page 3 of 5
NET2 AC-DC Series Data Sheet
Line to Ground
At 100% load
Line to Line
@254VAC
NET2-4350 Approved; NET2-4231 Pending
NET2-4350 Approved; NET2-4231 Pending
NET2-4350 Approved; NET2-4231 Pending
NET2-4350 Approved; NET2-4231 Pending
(209.6mm x 114.3mm x 40.4mm)
2600
MIN
MIN
-40
10
10
±2
10
30
B
B
8
1
2
0
5
8.25" x 4.50" x 1.59"
SIZE IMPACT
± 0.02
TYP
TYP
1
1
www.power-one.com
± 0.05
6.15
MAX
MAX
10k
40k
50
85
95
20
40
1
ASL Ft.
ASL Ft.
Class
Grms
UNITS
UNITS
%/°C
%RH
VDC
V/M
Gpk
Gpk
G
G
mA
kV
kV
kV
°C
°C
PK
PK

Related parts for NET2-4231