ACS-1024-LG Photon Vision Systems, Inc., ACS-1024-LG Datasheet - Page 10

no-image

ACS-1024-LG

Manufacturer Part Number
ACS-1024-LG
Description
Image Sensor, CMOS|CCD, 1026x1026 Pixels, 132pin LCC
Manufacturer
Photon Vision Systems, Inc.
Datasheet
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
15
16
17
44
45
46
47
48
49
51
52
53
54
55
56
57
58
M13
M14
M15
N12
N13
N14
N15
P13
R14
P14
R15
P15
L13
L14
Product DATASHEET ACS PDS0003 Subject to change without notice. Page 10 of 26
M3
N2
P1
R_DATA_9
M/S
R_DATA_10
M/S
R_DATA_11
M/S
ROW RESET
ROW TRANSFER
EOC
ACTIVE
RLP IN
EXT ANA SEL
CDS1
CDS0
C1
C0
R1
R0
CRST
RESET
Photon Vision Systems, Inc.
Digital Out - MAST
Bi-directional I/O
Digital In - SLAVE
Digital Out - MAST
Bi-directional I/O
Digital In - SLAVE
Digital Out - MAST
Bi-directional I/O
Digital In - SLAVE
Digital Out - MAST
Digital Input
Digital Input
Digital Output
Digital Input
Digital Input
Digital Input
0 Internal Video
1 External Input
Digital Input
CDS1 CDS0 Mode
0
0
1
1
Digital Input
See table, pin 40
Digital Input
C1 C0
Digital Input
Digital Input
R1
0
0
1
Digital Input
Digital Input
Digital Input
Copyright© 2002 Rev A
0
1
0
1
0 - 1X
1 - 2X
X - 4X
R0
0 – 1X
1 – 2X
0 – 4X
Full CDS
Quasi CDS
No CDS
Transfer and
Readout
addressed pixel. Pin must be connected whenever in SLAVE
mode, do not float.
Row address BIT 9 - If in SLAVE mode, input Row address for
random access. If in MASTER mode, output for currently
addressed pixel. Pin must be connected whenever in SLAVE
mode, do not float.
Row address BIT 10 - If in SLAVE mode, input Row address for
random access. If in MASTER mode, output for currently
addressed pixel. Pin must be connected whenever in SLAVE
mode, do not float.
Row address MSB BIT 11 - If in SLAVE mode, input Row
address for random access. If in MASTER mode, output for
currently addressed pixel. Pin must be connected whenever in
SLAVE mode, do not float.
In slave mode when TRUE LOW resets the selected row.
Pin must be connected whenever in SLAVE mode, do not float.
In slave mode when TRUE LOW this signal transfers charge from
the collection site to the storage site for the selected row
Pin must be connected whenever in SLAVE mode, do not float.
In slave mode when TRUE LOW CDS is completed for the
selected row
Pin must be connected whenever in SLAVE mode, do not float.
In slave mode this signal must go TRUE LOW within 1 1X clock
cycle after EOC goes true in order to begin readout of the selected
row
Pin must be connected whenever in SLAVE mode, do not float.
In slave mode this signal must go TRUE LOW for 1 1X clock to
initiate CDS on the selected row
Pin must be connected whenever in SLAVE mode, do not float.
This signal selects between the internal video and the external
analog input
Pin must be connected whenever in SLAVE mode, do not float.
Standard readout mode
Readout mode used for snapshot
Accumulate and Transfer – This is output without CDS, the user is
advised to change to CDS mode 1 to readout when sufficient
signal level is achieved.
Transfer and Readout.
Pin must be connected whenever in SLAVE mode, do not float.
Use in conjunction with pin 40.
Pin must be connected whenever in SLAVE mode, do not float.
Col Binning
1X - Device outputs full horizontal pixel resolution
2X - Every 2 rows are binned, horizontal resolution is divided by 2
Pin must be connected whenever in SLAVE mode, do not float.
4X - Every 4 rows are binned, horizontal resolution is divided by 4
Pin must be connected whenever in SLAVE mode, do not float.
See Above
Pin must be connected whenever in SLAVE mode, do not float.
Row Binning control
1X - Device outputs full vertical pixel resolution
2X - Every 2 rows are binned, vertical resolution is divided by 2
4X - Every 4 rows are binned, vertical resolution is divided by 4
Pin must be connected whenever in SLAVE mode, do not float.
See Above
Pin must be connected whenever in SLAVE mode, do not float.
In slave mode when TRUE LOW CRST performs a global reset on
all pixel
Note: TX must also be TRUE.
Pin must be connected whenever in SLAVE mode, do not float.
TREU LOW Forces master reset of state machine to default
values.

Related parts for ACS-1024-LG