KSC-3000 Kodak, KSC-3000 Datasheet - Page 18

no-image

KSC-3000

Manufacturer Part Number
KSC-3000
Description
Color Processor Firmware Code Providing 24-bit RGB Color Image Data at 1 Megapixel Resolution And 30 Frames/second.
Manufacturer
Kodak
Datasheet
IMAGE SENSOR SOLUTIONS
18
900 - CFF
100 - 4FF
500 - 8FF
Serial I/F Control (Register 000)
Default: 0
This register contains a test bit that is used to turn on/off the DS4 LED.
TIG Control (Register 001)
Default: 0
This register controls the behavior of the test image generator (TIG). The TIG is an internal pattern generator that
emulates an incoming image stream so that the internal operation of the device can be tested without being
connected to an input device. The TIG is intended as a debug tool only. Note that the pixel clock input must still be
operational in order to generate a TIG image.
The TIG is capable of producing four different pattern types according to the setting of the image generation mode
bits. The LFSR is a pseudo-random pattern, the pixel ramp increments each new output pixel by one, the line ramp
increments the output pixel by one for each new line that is generated, and the frame ramp increments the output
pixel by one for each new frame that is generated. Note that when viewed on an output device, the LFSR pattern
will look like dynamic static, the pixel and line ramps will create rolling images, and the frame ramp will produce a
fade to black effect.
Also, the number of sequential frames to be generated by the TIG is specified by setting the num frames mode bits.
Options available are one frame, ten frames, 1000 frames or a continuous stream of frames until the TIG is disabled.
Additionally, the blanking interval between lines and the blanking interval between frames can also be adjusted on
the output of the TIG to more closely emulate the timing of a specific input device. The pixel blanking interval was
not implemented and should be left at its reset value. The TIG line blanking interval should never be set lower than
the line blanking interval specified in the Gamma LUT control register when the TIG is enabled.
The TIG may be used in conjunction with the signature analyzer to perform a built in self test (BIST) on the device
to verify its internal functionality.
SIG Control (Register 002)
Default: 0
K S C - 3 0 0 0 R e v 1 . 0
8
8
8
Read/Write
Read/Write
Read/Write
w w w . k o d a k . c o m / g o / i m a g e r s
Green Gamma LUT
Blue Gamma LUT
Red Gamma LUT
Table 8 – KSC-3000 Memory Map
22:12 Line location (row)
7:0
7:0
7:0
11
23
5 8 5 - 7 2 2 - 4 3 8 5
Green pixel value
Blue pixel value
Red pixel value
Reserved
Reserved
E m a i l : i m a g e r s @ k o d a k . c o m
unsigned
unsigned
unsigned
unsigned
CCIR709
CCIR709
CCIR709
0
0
0
no defect correction*
*Reset values imply
Defects in first/last
row are ignored

Related parts for KSC-3000