PIC16C72-02/SS Microchip Technology, PIC16C72-02/SS Datasheet - Page 14

no-image

PIC16C72-02/SS

Manufacturer Part Number
PIC16C72-02/SS
Description
8-Bit CMOS Microcontrollers with A/D Converter
Manufacturer
Microchip Technology
Datasheet
PIC16C72 Series
2.2.2.6
The Power Control (PCON) register contains a flag bit
to allow differentiation between a Power-on Reset
(POR) to an external MCLR Reset or WDT Reset.
Those devices with brown-out detection circuitry con-
tain an additional bit to differentiate a Brown-out Reset
condition from a Power-on Reset condition.
FIGURE 2-8:
DS39016A-page 14
bit7
bit 7-2: Unimplemented: Read as '0'
bit 1:
bit 0:
U-0
PCON REGISTER
POR: Power-on Reset Status bit
1 = No Power-on Reset occurred
0 = A Power-on Reset occurred (must be set in software after a Power-on Reset occurs)
BOR: Brown-out Reset Status bit
1 = No Brown-out Reset occurred
0 = A Brown-out Reset occurred (must be set in software after a Brown-out Reset occurs)
U-0
PCON REGISTER (ADDRESS 8Eh)
U-0
U-0
U-0
Preliminary
U-0
R/W-0
POR
Note:
BOR is unknown on Power-on Reset. It
must then be set by the user and checked
on subsequent resets to see if BOR is
clear, indicating a brown-out has occurred.
The BOR status bit is a don't care and is
not necessarily predictable if the brown-out
circuit is disabled (by clearing the BODEN
bit in the Configuration word).
R/W-q
BOR
bit0
R = Readable bit
W = Writable bit
U = Unimplemented bit,
- n = Value at POR reset
1998 Microchip Technology Inc.
read as ‘0’