Summary The PSC series of positive switching regulators is designed as power supply modules for electronic systems. Their ma- jor advantages include a high level of efficiency that re- mains virtually constant over the entire input voltage range, high reliability, ...
Page 2
Part Number Description Positive switching regulator in case C03 .................... PSC Nominal output voltage in volt (5A for 5.1 V) ......... Nominal output current in ampere ............................ Operational ambient temperature range T –25 to ...
Page 3
Electrical Input Data General Conditions 25°C, unless T A Table 2a: Input data Input Characteristics Conditions V Operating input voltage min Min. diff. voltage V – ...
Page 4
Electrical Output Data General Conditions: – 25°C, unless T is specified A C – With R or option P, output voltage V o Table 3a: Output data Output Characteristics Conditions V Output voltage nom 1 ...
Page 5
... The out- put protection is not designed to withstand externally ap- plied overvoltages. The user should ensure that systems with Power-One power supplies, in the event of a failure, do not result in an unsafe condition (fail-safe). REV. MAY 12, 2004 PSC Series Extended Data Sheet ...
Page 6
Auxiliary Functions i Inhibit for Remote On and Off Note: With open i-input, output is enabled ( V The inhibit input allows the switching regulator output to be disabled via a control signal. In systems with several units, this feature ...
Page 7
100 using R between R and G (Go-): o o nom 1 4000 Ω • ≈ ––––––––––– ≈ ––––––––––– – nom o ...
Page 8
Electromagnetic Emission For emission levels refer to: Electrical Input Data . Fig. 11 Typical disturbance voltage (quasi-peak) at the input ac- cording to EN 55011/22 measured at V Immunity to Environmental Conditions Table 6: Mechanical stress Test Method Standard Ca ...
Page 9
... VDC This test is performed in the factory as routine test in accordance with EN50116, IEC/EN 60950 and UL 1950 and should not be repeated in the field. Power-One will not honour any guarantee claims resulting from electric strength field tests. Page ...
Page 10
Safety of Operator Accessible Output Circuit If the output circuit of a switching regulator is operator-ac- cessible, it shall be an SELV circuit according to IEC/EN 60950 related safety standards The following table shows some possible installation con- figurations, compliance ...
Page 11
Description of Options -9 Extended Temperature Range The operational ambient temperature range is extended –40 to 71° –40 to 95° Potentiometer Option P excludes R function. The output voltage V ...
Page 12
... For more detailed information please refer to: Accessories on the Power-One homepage. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. ...
Page 13
... EMC directive can be presumed. Uster, 14 Oct. 2003 REV. MAY 12, 2004 PSC Series Extended Data Sheet Positive Switching Regulators (Industrial) We Power-One AG Power-One AG Rolf Baldauf Johann Milavec Director Engineering Director Projects and IP Page ...