PSC126-7LIRPCD Power-One, PSC126-7LIRPCD Datasheet

no-image

PSC126-7LIRPCD

Manufacturer Part Number
PSC126-7LIRPCD
Description
Psc Series Extended Positive Switching Regulators Rugged
Manufacturer
Power-One
Datasheet
Model Selection and Key Data
Table 1: Type survey
1
2
Non standard input/output configurations or special custom adaptions are available on request.
REV. MAY 12, 2004
Summary
The PSC series of positive switching regulators is designed
as power supply modules for electronic systems. Their ma-
jor advantages include a high level of efficiency that re-
mains virtually constant over the entire input voltage range,
high reliability, low ripple and excellent dynamic response.
Table of Contents
Summary .......................................................................... 1
Model Selection and Key Data ......................................... 1
Part Number Description ................................................. 2
Functional Description ..................................................... 2
Electrical Input Data ......................................................... 3
Electrical Output Data ...................................................... 4
Auxiliary Functions ........................................................... 6
Surges uo to 156 V for 2 s. See also: Electrical Input Data: D V
Efficiency at V
V
Output
voltage
o nom
12
15
24
36
48
[V]
i nom
and I
I
Output
current
o nom
o nom
6
6
6
6
6
[A]
.
voltage range
18 - 144
22 - 144
31 - 144
44 - 144
58 - 144
V
Input
i
[V]
88
3.5"
1
151
5.9"
V
voltage
Input
i nom
32
1.3"
Page
60
60
60
80
80
Page 1 of 13
[V]
io min
Positive Switching Regulators (Rugged)
. (min. difference V
Modules with input voltages up to 144 V are specially de-
signed for battery driven mobile applications. The case de-
sign allows operation at nominal load up to 71°C without
additional cooling.
Electromagnetic Compatibility (EMC) ............................. 7
Immunity to Environmental Conditions ........................... 8
Mechanical Data ............................................................. 9
Safety and Installation Instructions .................................. 9
Description of Options ................................................... 11
Accessories ................................................................... 12
EC-Declaration of Conformity ....................................... 13
• High efficiency up to 97%
• Extremely wide input voltage range
• Very good dynamic properties
• Input undervoltage lock-out
• External output voltage adjustment and inhibit
• Two temperature ranges
• Continuous no-load and short-circuit proof
• No derating
Safety according to IEC/EN 60950
η
Input voltage up to 144 VDC
Single output of 12 - 48 VDC
No input to output isolation
min
88
89
93
95
96
Efficiency
[%]
PSC Series Extended Data Sheet
η
typ
i
89
90
94
96
97
- V
2
[%]
o
)
designation
PSC 126-7iR
PSC 156-7iR
PSC 246-7iR
PSC 366-7iR
PSC 486-7iR
Type
-9, L, P, C, D
Options
Page

Related parts for PSC126-7LIRPCD

PSC126-7LIRPCD Summary of contents

Page 1

Summary The PSC series of positive switching regulators is designed as power supply modules for electronic systems. Their ma- jor advantages include a high level of efficiency that re- mains virtually constant over the entire input voltage range, high reliability, ...

Page 2

Part Number Description Positive switching regulator in case C03 ................... PSC Nominal output voltage in volt ................................ Nominal output current in ampere .................................. 6 Operational ambient temperature range T –25 to 71°C ......................................................... -7 –40 to 71°C ...

Page 3

Electrical Input Data General Conditions 25°C, unless T A Table 2a: Input data Input Characteristics Conditions 1 V Operating input voltage min D V Min. diff. voltage V – ...

Page 4

Electrical Output Data General Conditions: – 25°C, unless T is specified A C – With R or option P, output voltage V o Table 3a: Output data Output Characteristics Conditions V Output voltage nom 1 ...

Page 5

... The out- put protection is not designed to withstand externally ap- plied overvoltages. The user should ensure that systems with Power-One power supplies, in the event of a failure, do not result in an unsafe condition (fail-safe). Parallel and Series Connection Outputs of equal nominal voltages can be parallel-con- nected ...

Page 6

nom 1 0 Inhibit 1 0 Fig. 8 Output response as a function of inhibit signal R Control for Output Voltage Adjustment ≈ V Note: With open R input ...

Page 7

Electromagnetic Compatibility (EMC) Electromagnetic Immunity General condition: Case not earthed. Table 5: Immunity type tests 1 Phenomenon Standard Class Level 1 MHz burst IEC III disturbance 60255-22-1 Voltage surge IEC 60571-1 Electrostatic IEC/EN 4 contact discharge discharge 61000-4-2 Electromagnetic IEC/EN ...

Page 8

Immunity to Environmental Conditions Table 6: Mechanical stress Test Method Standard Ca Damp heat IEC/DIN 60068-2-3 steady state MIL-STD-810D section 507.2 Ea Shock IEC/EN/DIN 60068-2-27 (half-sinusoidal) MIL-STD-810D section 516.3 Eb Bump IEC/EN/DIN 60068-2-29 (half-sinusoidal) MIL-STD-810D section 516 Vibration ...

Page 9

... VDC This test is performed in the factory as routine test in accordance with EN50116, IEC/EN 60950 and UL 1950 and should not be repeated in the field. Power-One will not honour any guarantee claims resulting from electric strength field tests. Page ...

Page 10

Safety of Operator Accessible Output Circuit If the output circuit of a switching regulator is operator-ac- cessible, it shall be an SELV circuit according to IEC/EN 60950 related safety standards. The following table shows some possible installation con- figurations, compliance ...

Page 11

Description of Options -9 Extended Temperature Range The operational ambient temperature range is extended –40 to 71° –40 to 95° Potentiometer Option P excludes R function. The output voltage V ...

Page 12

... For more detailed information please refer to: Accessories on the Power-One homepage. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. ...

Page 13

... EMC directive can be presumed. Uster, 14 Oct. 2003 REV. MAY 12, 2004 PSC Series Extended Data Sheet Positive Switching Regulators (Rugged) We Power-One AG Power-One AG Rolf Baldauf Johann Milavec Director Engineering Director Projects and IP Page ...