MJWI10-48D12 Minmax Technology Co., Ltd., MJWI10-48D12 Datasheet - Page 6

no-image

MJWI10-48D12

Manufacturer Part Number
MJWI10-48D12
Description
10w, Wide Input Range Dip, Single & Dual Output Dc/dc Converters
Manufacturer
Minmax Technology Co., Ltd.
Datasheet
Test Configurations
Input Reflected-Ripple Current Test Setup
Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 KHz) to
simulate source impedance.
module, measurement bandwidth is 0-500 KHz.
Peak-to-Peak Output Noise Measurement Test
socket, measurement bandwidth is 0-20 MHz. Position the
load between 50 mm and 75 mm from the DC/DC Converter.
Design & Feature Considerations
Remote On/Off
logic high voltage on the remote on/off pin, and off during a
logic low.
a switch to control the voltage between the on/off terminal and
the -Vin terminal.
low is -500uA.
on/off terminal (2.5 to 50V) is 500uA.
REV:10 2010/06/03
Input reflected-ripple current is measured with a inductor
Capacitor Cin, offsets possible battery impedance .
Current ripple is measured at the input terminals of the
Use a Cout 0.47uF ceramic capacitor.
Scope measurement should be made by using a BNC
Positive logic remote on/off turns the module on during a
To turn the power module on and off, the user must supply
The switch can be an open collector or equivalent.
A logic low is 0V to 1V.
A logic high is 2.5V to 50V.
The maximum sink current at on/off terminal during a logic
The maximum allowable leakage current of the switch at
+Vin
+Vin
-Vin
Dual Output
-Vin
To Oscilloscope
Single Output
Converter
+
DC / DC
Battery
Converter
DC / DC
+
Cin
+Out
+Out
Com.
-Out
-Out
Lin
Copper Strip
Copper Strip
Copper Strip
Copper Strip
Copper Strip
Current
Probe
Cout
Cout
Cout
+Vin
-Vin
Converter
DC / DC
+Out
Scope
-Out
Scope
Scope
Resistive
Resistive
Load
Load
Load
MINMAX
Overcurrent Protection
the unit is equipped with internal current limiting circuitry and
can endure current limiting for an unlimited duration. At the
point of current-limit inception, the unit shifts from voltage
control to current control. The unit operates normally once the
output current is brought back into its specified range.
Input Source Impedance
ac-impedance input source. Highly inductive source
impedances can affect the stability of the power module.
output loading is high, it may be necessary to use a capacitor
at the input to ensure startup.
ensure stability of the unit, it is recommended to use a good
quality low Equivalent Series Resistance (ESR < 1.0[ at 100
KHz) capacitor of a 6.8uF for the 24V and 48V devices
To provide protection in a fault (output overload) condition,
The power module should be connected to a low
In applications where power is supplied over long lines and
Capacitor mounted close to the power module helps
DC Power
Source
+
-
MJWI10 Series
+
Cin
+Vin
-Vin
Converter
DC / DC
+Out
-Out
Load
6