MJWI10-48D12 Minmax Technology Co., Ltd., MJWI10-48D12 Datasheet
MJWI10-48D12
Related parts for MJWI10-48D12
MJWI10-48D12 Summary of contents
Page 1
... I/O Isolation Minmax's new launched MJWI10 series comprising 16 different models. Packing up to 10W of power into a 1x1x0.4 inch package, with efficiency as high as 87%. The MJWI10 has wide input ranges of 9-36VDC and 18-75VDC and is available in output voltages of 3.3V, 5V, 5.1V, 12V, 15V, {5V, {12V and {15VDC. Other features include soft start, continuous short circuit protection, remote on/off, six-sided shielded case, and EN55022 Class A conducted noise compliance minimizes design-in time, cost and eliminate the need for external filtering ...
Page 2
... MJWI10-24S15 MJWI10-24D05 MJWI10-24D12 MJWI10-24D15 MJWI10-48S033 MJWI10-48S05 MJWI10-48S051 MJWI10-48S12 MJWI10-48S15 MJWI10-48D05 MJWI10-48D12 MJWI10-48D15 Capacitive Load Models by Vout 3.3V Maximum Capacitive Load 560 # For each output Input Fuse Selection Guide 24V Input Models 2000mA Slow - Blow Type Input Specifications Parameter Start Voltage ...
Page 3
... Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 6. All DC/DC converters should be externally fused at the front end for protection. 7. Other input and output voltage may be available, please contact factory. 8. Specifications subject to change without notice order the converter with heatsink, please add a suffix -HS (e.g. MJWI10-24S05/HS). 3 Conditions Dual Output, Balanced Loads Vin=Min ...
Page 4
... Input Voltage Transient Rating 130 125 120 115 110 105 100 10uS REV:10 2010/06/03 Dual Output +Vo +Vin -Vo -Vin Ref.Amp On/Off 48VDC Input Models 24VDC Input Models 100uS 1mS MINMAX MJWI10 Series LC Filter A A PWM Ref.Amp Isolation 10mS +Vo Com. -Vo 100mS 4 ...
Page 5
... Efficiency vs Input Voltage ( MJWI10-48D15 ) 100 18V 20 48V 10 75V 100 Efficiency vs Output Load ( MJWI10-48D15 ) 100 400LFM 200LFM 100 110 -40 ] MINMAX Input Voltage( ...
Page 6
... Equivalent Series Resistance (ESR < 1.0[ at 100 KHz) capacitor of a 6.8uF for the 24V and 48V devices DC Power Source Resistive Scope Load Scope Resistive Load Scope MINMAX MJWI10 Series + +Vin +Out + Converter Cin - -Vin -Out Load 6 ...
Page 7
... Converter - -Vin -Out Maximum Capacitive Load The MJWI10 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet. ...
Page 8
... Heat-Sink reliability of DC/DC converters at high operating temperature Thermal Pad atmosphere. Clamp 2.To upgrade the operating temperature of DC/DC converters, Converter please refer to Derating Curve. Inches X.XX{0.01 X.XXX{0.005 {0.002 MINMAX MJWI10 Series Pin Single Output 1 +Vin 2 -Vin 3 +Vout 4 No Pin 5 -Vout 6 ...