Specifications<AC /DC >
Output Characteristic
O utput Voltage [V]
O utput Current [A]
Voltage Adjust Range
R ipple and Noise [mVp-p](maximum) *3
R egulation
a.Statistic Line Regulation [mV](maximum)
b.Statistic Load Regulation [mV](maximum)
c.T emperature Coefficient *4
d.D rift[mV](maximum) *5
e.Dynamic Load Regulation [mV](typical) *6
f.Recovery T ime *6
R ise up time
H old up time
Functions
O vercurrent Protection ≧ 110% of Rated
O utput Current[A]
O vervoltage Protection ≧ 110% of Rated
O utput Voltage[V]
R emote Sense
R emote O n/O ff
Environmental
O perating T emperature *7
O perating Humidity
Storage T emperature
Storage Humidity
W ithstanding Voltage
Isolation Resistance
Vibration
Shock
C ooling
? Leakage Current
? C onducted line noise
? Safety
W eight (typical)
? MT BF [H]
? Switching Frequency[kHz](typical) *8
C onditions:
*1 at cold start
*2 at DC 130V input and rated output
*3 measured by a bayonet probe at the end of a pair of 20cm long wires terminated with a 47uF electrolytic capacitor
*4 at -5 to +50 ℃ /enclosed type: at -5 to +40 ℃
*5 for 7hour period after 1hour warm-up at 25 ℃ and rated input/output
*6 when output current changed from 25% to 75% of rated output current rapidly at AC100V input
*7 safety approved at 40 ℃
*8 variable on input voltage and load conditions
MRA**SA Specification
and a 0.1uF film capacitor in parallel at a 0 to 100MHz bandwidth
25W AT T S/SING LE
M R A**SA
MR A05SA-U
5-10H z:10m m double am plitude,10-55H z:19.6m /s
5.25
5.50
5.0
150
150
40
50
40
40
5
Primary-Secondary-Frame G round 50MΩ (minimum) by D C500V insulation tester
1mA(maximum) at 25 ℃ ,rated input/output and rated input frequency
+/- 10% of Rated O utput Voltage(at no load within the input range)
output shutdown(to reset,leave 60seconds after shut-off)
MR A12SA-U
Secondary-Frame G round AC500V for 1minute
2.21
13.2
500mS(maximum) at 25 ℃ and rated input/output
2.1
220
120
360
Primary-Frame G round AC1,500V for 1minute
20m S(minimum) at 25 ℃ and rated input/output
12
96
75
40
Primary-Secondary
Current Limiting with automatic recovery
-5 to +50 ℃ /enclosed type: -5 to +40 ℃
Built to meet FCC Part15-B Class B
C-U L:CSA C22.2 No.234(Level 3)
30 to 85% RH(non-condensing)
10 to 85% RH(non-condensing)
Built to meet VC CI Class B
220g/enclosed type:250g
2
,20m inutes' period for 60m inutes each along X ,Y,Z axes(non-operating)
0.3mS(T ypical)
MRA15SA-U
not available
not available
-20 to +85 ℃
U L:UL1950
Convection
0.03% / ℃
294m/s
640,000
M odel
1.79
16.5
1.7
250
120
150
450
15
90
45
AC2,000V for 1minute
2
MRA24SA-U
1.16
26.4
1.1
340
192
240
135
720
24
45
MRA48SA-U
1440
0.58
52.8
0.55
580
384
480
255
48
45

Related parts for MRA05SA-U