OC1-12SC2448-U ETA-USA, OC1-12SC2448-U Datasheet

DC/DC Converters & Regulators 20.4-56V TO 12V

OC1-12SC2448-U

Manufacturer Part Number
OC1-12SC2448-U
Description
DC/DC Converters & Regulators 20.4-56V TO 12V
Manufacturer
ETA-USA
Series
OC1r
Datasheet

Specifications of OC1-12SC2448-U

Output Power
16 W
Input Voltage Range
20.4 V to 56 V
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
1.3 A
Package / Case Size
1.26 in x 0.84 in x 0.39 in
Output Voltage
12 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Specifications<DC/DC>
Input Characteristic
Input Voltage
Input Range
Inrush Current
Input Range
Input Current when Remote controll is off
Line Back Noise [mVp-p](typical)
Efficiency [%] (typical) *1
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
at no load [mA](typical)
at full load[mA](typical)
OC1**SC2448
SINGLE
DC[V]
DC[V]
[A]
OC1-3.3SC2448 OC1-05SC2448 OC1-06SC2448 OC1-09SC2448
0.39
260
24
74
4
1
139
0.9
48
69
5
1
0.42
Block Diagram
355
24
81
2
1
0.93
187
1.3
48
78
2
0.42
416
1.2
24
84
2
0.92
218
1.3
48
80
2
Not specified
20.4 to 56
Model
0.37
596
1.5
24
88
3
312
0.9
48
85
DC-DC CONVERTER
2
2
NON-ISOLATED
4.6~28.8 WATT
OC1V –SC2448
OC1-12SC2448
0.34
714
1.5
24
91
4
1.47
369
2.0
48
88
4
OC1-15SC2448
806
0.2
1.5
24
93
6
416
1.5
2.5
48
90
4

Related parts for OC1-12SC2448-U

OC1-12SC2448-U Summary of contents

Page 1

... Specifications<DC/DC> OC1**SC2448 OC1-3.3SC2448 OC1-05SC2448 OC1-06SC2448 OC1-09SC2448 SINGLE Input Characteristic Input Voltage DC[V] Input Range DC[V] Inrush Current [A] Input Range at no load [mA](typical) at full load[mA](typical) Input Current when Remote controll is off Line Back Noise [mVp-p](typical) Efficiency [%] (typical) *1 ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com ...

Page 2

... Turn on by inputing voltage(4.5 to 56V) between "RC"pin and "0V"pin .Put a 5k ohm resistor between "+ in"pin and "RC"pin when remote on/off is not used 2%/℃ (50℃ to 71℃ ) (out of warranty≧ 71℃ ) 20-90%/RH(non-condensing 90%/RH(non-condensing) 5-10Hz:10mm double amplitude,10-55Hz:2G,3minutes' period for 30minutes each along X,Y,Z axes(non-operating) Model OC1-09SC2448 OC1-12SC2448 1.4 1.4 1.3 180 ...

Page 3

... ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Dimension Diagram ...

Page 4

... Efficiency Curve ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com OCP Curve ...