MASWSS0024 Tyco Electronics, MASWSS0024 Datasheet - Page 2

no-image

MASWSS0024

Manufacturer Part Number
MASWSS0024
Description
Spdt High Isolation Terminated Switch, 0.5 - 3.0 Ghz
Manufacturer
Tyco Electronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MASWSS0024
Manufacturer:
MA/COM
Quantity:
20 000
Part Number:
MASWSS0024TR
Manufacturer:
MA/COM
Quantity:
5 000
Part Number:
MASWSS0024TR
Manufacturer:
MACOM
Quantity:
20 000
Part Number:
MASWSS0024TR-3000
Manufacturer:
M/A-COM
Quantity:
933
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
SPDT High Isolation Terminated Switch,
0.01 - 3.0 GHz
Truth Table
Electrical Specifications
5. External DC blocking capacitors are required on all RF ports (47 pF capacitors are recommended). Use larger value capacitors for lower
6. Terminated return loss is governed by blocking capacitors internal to the device; see applications plot.
7. 3.0V < V
frequency operation (e.g. use 10,000 pF capacitors to optimize insertion and return loss at frequencies below 50 MHz).
V1
0
1
Logic Level
Insertion Loss
Parameter
Return Loss
Trise, Tfall
Transients
V
Ton, Toff
V
Isolation
Input IP
Input IP
C
HIGH
LO
< 8.0V
“0”
“1”
2
3
V2
1
0
RFC-RF1
2-Tone 900 MHz, 5 MHz spacing (V
2-Tone 900 MHz, 5 MHz spacing (V
Off
On
Voltage Level
5
: T
10% to 90% RF & 90% to 10% RF
V
V
0 ± 0.2V
C
C
50% of V
± 0.2V
A
= 5.0V square wave, in-band
= 25°C, V
Test Conditions
RFC-RF2
0.01 - 0.5 GHz
0.01 - 0.5 GHz
0.01 - 0.5 GHz
0.5 - 1.0 GHz
1.0 - 2.0 GHz
2.0 - 3.0 GHz
0.5 - 1.0 GHz
1.0 - 2.0 GHz
2.0 - 3.0 GHz
0.5 - 1.0 GHz
1.0 - 2.0 GHz
2.0 - 3.0 GHz
C
On
Off
7
to 10% / 90% RF
CTL
6
= 0, 5.0V
C
C
= 5.0V)
= 5.0V)
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
(unless otherwise specified)
Units
dBm
dBm
mV
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
nS
nS
Min
51
48
43
Typ
0.75
0.5
0.6
0.7
MASWSS0024
59
54
52
48
20
20
20
20
83
43
24
15
12
Max
0.7
0.8
0.9
V6

Related parts for MASWSS0024