ZY2160 Power-One, ZY2160 Datasheet - Page 12

no-image

ZY2160

Manufacturer Part Number
ZY2160
Description
Zy2160 60a No-bus Pol
Manufacturer
Power-One
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ZY2160G
Manufacturer:
RENESAS
Quantity:
3 000
Part Number:
ZY2160G
Manufacturer:
POWER-ONE
Quantity:
20 000
8.
The ZY2160 POL converters do not provide
isolation from input to output. The input devices
powering ZY2160 must provide relevant isolation
requirements according to all IEC60950 based
standards.
converter needs to receive safety agency approval,
certain rules must be followed in the design of the
system.
clearance requirements of the end-use safety
requirements
requirements are included in UL60950 - CSA60950-
00 and EN60950, although specific applications may
have other or additional requirements.
The ZY2160 POL converters have no internal fuse.
If required, the external fuse needs to be provided to
protect the converter from catastrophic failure. Refer
to the “Input Fuse Selection for DC/DC converters”
application note on
selection of the input fuse. Both input traces and the
chassis ground trace (if applicable) must be capable
of conducting a current of 1.5 times the value of the
fuse without opening. The fuse must not be placed
in the grounded input line.
Abnormal
conducted with the POL input protected by a fast-
acting 32V, 25A, fuse. If a fuse rated greater than
25A is used, additional testing may be required.
In order for the output of the ZY2160 POL converter
to be considered as SELV (Safety Extra Low
Voltage),
standards, the input to the POL needs to be supplied
by an isolated secondary source providing a SELV
also.
9.
9.1
The open drain input/output with the internal pull-up
resistor. The POL converter pulls its OK pin low, if a
fault occurs. Pulling low the OK input by an external
circuitry turns off the POL converter.
9.2
The bidirectional input/output with the internal pull-up
resistor.
master, the SYNC line propagates clock to other
POL converters. If the POL converter is configured
ZD-01966 REV. 1.0
Safety
Pin and Feature Description
OK, Fault Status
SYNC, Frequency Synchronization Line
If the POL converter is configured as a
In particular, all of the creepage and
according
and
Nevertheless, if the system using the
must
component
www.power-one.com
to
be
all
observed.
failure
IEC60950
tests
www.power-one.com
for proper
These
based
were
8V to 14V Input
ZY2160 60A No-Bus POL Data Sheet
as a slave, the internal clock recovery circuit
synchronizes the POL converter to the clock of the
SYNC line.
9.3
The input with the internal pull-up resistor. When the
pin is left floating, the switching frequency is
determined by an external clock applied to the SYNC
pin.
converter as a master. The master determines the
clock on the SYNC line.
9.4
The open drain input/output with the internal pull-up
resistor. The pin is pulled low by the POL converter,
if the output voltage is outside of the window defined
by the Power Good High and Low thresholds.
Note: See the No-Bus Application Note for recommendations on
9.5
Inputs with internal pull-ups to select one of 2 sets of
digital filter coefficients optimized for different
characteristics of output capacitance.
9.6
The open drain digital input/output with the internal
pull-up resistor. The duty cycle of the digital signal is
proportional to the output current of the POL
converter.
shall be avoided.
9.7
The output of the 2V internal voltage reference that
is used to program the output voltage of the POL
converter.
9.8
The input of the TRIM comparator for the output
voltage programming.
The output voltage is programmed by a single
resistor connected between MARGIN and TRIM
pins.
9.9
The input with the internal pull-up resistor. The POL
converter is turned off, when the pin is pulled low
9.10 –VS and +VS
The differential voltage input of the POL converter
feedback loop.
PG deglitching.
IM, Interleave Mode
PG, Power Good
CCA, Compensation Coefficient Address
CS, Current Share/Sense Bus
MARGIN, Output Voltage Margining
TRIM, Output Voltage Trim
EN, Enable
Pulling the IM pin low configures a POL
External capacitive loading of the pin
0.5V to 2.75V Output
Page 12 of 14

Related parts for ZY2160