VN771 STMicroelectronics, VN771 Datasheet - Page 4

no-image

VN771

Manufacturer Part Number
VN771
Description
Quad Smart Power Solid State Relay For Complete H-bridge Configurations
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
VN771K
Manufacturer:
ST
0
Part Number:
VN771K
Manufacturer:
ST
Quantity:
20 000
Part Number:
VN771K13TR
Manufacturer:
ST
0
Part Number:
VN771KP
Manufacturer:
ST
Quantity:
20 000
Part Number:
VN771KP-E
Manufacturer:
ST
0
Part Number:
VN771KPTR-E
Manufacturer:
SGS
Quantity:
248
Part Number:
VN771KPTR-E
Manufacturer:
ST
0
Part Number:
VN771KPTR-E
Manufacturer:
ST进口原装
Quantity:
20 000
Part Number:
VN771P
Manufacturer:
ST
Quantity:
32
Part Number:
VN771P
Manufacturer:
ST
0
Part Number:
VN771P
Manufacturer:
ST
Quantity:
20 000
VN771
ABSOLUTE MAXIMUM RATING (-40
HIGH SIDE SWITCH
4/10
PROTECTION CIRCUITS
DUAL HIGH SIDE SWITCH
The simplest way to protect the device against a
continuous reverse battery voltage (-26V) is to
insert a a small resistor between pin 2 (GND) and
ground. The suggested resistance value is about
150 . In any case the maximum voltage drop on
this resistor should not overcome 0.5V.
TRUTH TABLE (for Dual high-side switch only)
NOTE: The low-side switches have the fault feedback which can be detected by monitoring the voltage at the input pins.
L = Logic LOW, H = Logic HIGH, X = Don’t care
Normal Operation
Under-voltage
T hermal Shutdown
O pen Load
O utput Shorted to V
Symb ol
V
(BR)DSS
I
-V
V
I
T
STAT
P
OUT
I
I
ESD
T
IN
s tg
R
tot
CC
j
Drain-Source Brekdown Voltage
Output Current (continuous)
Reverse O utput Current
Input Current
Reverse Supply Current
Status Current
Electrostatic Discharge (C = 100 pF, R = 1.5 K )
Power Dissipation @ T
Junction Operating Temperature
Storage Temperature
CC
Channel 1
Channel 2
Channel 1
Channel 2
Channel 1
Channel 2
c
= 25
Parameter
o
o
C < T
C
INPUT 1
H
H
X
H
X
H
X
H
X
L
L
L
L
L
L
j
< 150
o
INPUT 2
If there is no need for the control unit to handle
external analog signals referred to the power
GND, the best approach is to connect the
reference potential of the control unit to the
device ground (see application circuit in fig. 3),
which becomes the common signal GND for the
whole control board avoiding shift of V
V
C)
stat
H
H
X
X
H
X
H
X
H
L
L
L
L
L
L
.
SO URCE 1 SOURCE 2 DIAG NO STIC
H
H
H
H
H
L
L
L
L
X
L
X
L
X
L
Internally Limited
-40 to 150
-55 to 150
H
H
H
H
H
Value
X
X
X
L
L
L
L
L
L
L
2000
-14
40
14
-4
10
10
ih
H
H
H
H
H
L
L
L
L
L
L
L
L
L
L
, V
Unit
mA
mA
il
o
o
W
V
A
A
V
V
C
C
and

Related parts for VN771