STLM75 STMicroelectronics, STLM75 Datasheet - Page 13

no-image

STLM75

Manufacturer Part Number
STLM75
Description
Digital Temperature Sensor And Thermal Watchdog
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STLM75DS2E
Manufacturer:
ST
Quantity:
20 000
Part Number:
STLM75DS2F
Manufacturer:
ST
Quantity:
20 000
Part Number:
STLM75DS2F
0
Part Number:
STLM75M2E
Manufacturer:
AT&T
Quantity:
6 218
Part Number:
STLM75M2E
Manufacturer:
ST
0
Part Number:
STLM75M2E
Manufacturer:
ST
Quantity:
20 000
Part Number:
STLM75M2F
Manufacturer:
STMicroelectronics
Quantity:
1 850
Part Number:
STLM75M2F
Manufacturer:
STM
Quantity:
280
Part Number:
STLM75M2F
Manufacturer:
ST
0
Part Number:
STLM75M2F
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
STLM75M2F
Quantity:
2 500
2.4
Note:
Interrupt mode
In Interrupt mode, the OS output first becomes active when the measured temperature
exceeds the T
Configuration register. Once activated, the OS can only be cleared by either putting the
STLM75 into Shutdown mode or by reading from any register (temperature, configuration,
T
when the measured temperature falls below the T
equal to the FT value.
The OS can only be cleared by putting the device into Shutdown mode or reading any
register. Thus, this interrupt/clear process is cyclical between the T
T
the OS/INT pin occur only when the STLM75 is read or placed into Shutdown mode.
Otherwise, OS/INT would remain active independently for any event.
Figure 5.
1. These interrupt mode resets of O.S. occur only when STLM75 is read or placed in shutdown. Otherwise,
OS
OS
O.S. would remain active indefinitely for any event..
, or T
, clear, T
HYS
HYS
OS output temperature response diagram
) on the device. Once the OS has been deactivated, it will only be reactivated
OS
, clear, T
value a consecutive number of times as determined by the FT value in the
Figure 5
OS
, clear, T
illustrates typical OS output temperature response.
HYS
, clear, and so forth). These interrupt mode resets of
HYS
value a consecutive number of times
OS
and T
HYS
events (i.e.,
13/37

Related parts for STLM75