S1D12400 Series
3. Vertical double-size display register
4. Display ON/OFF register
5. Power save register
6. Power control register
7. System set register
8. Electronic volume
9. Static icon ON/OFF control
6–22
LB4 = 0
LB3 = 0
LB2 = 0
LB1 = 0
DD4 = 0
DD3 = 0
DD2 = 0
DD1 = 0
C = 0
B = 0
D = 0
RE = 0
O = 0
PS = 0
HPM = 0 : High power mode OFF
VC = 0
VF = 0
P = 0
IRS = 1
BAS = 0
IR1,0 = 00 : Rb/Ra = small
CG = 0
CS = 0
SS = 0
R1, 0 = 0 : Standard ROM + OPTION ROM1
(0,0,0,0,0)
: DDRAM line 4 blink OFF
: DDRAM line 3 blink OFF
: DDRAM line 2 blink OFF
: DDRAM line 1 blink OFF
: Line 4 is displayed in standard form.
: Line 3 is displayed in standard form.
: Line 2 is displayed in standard form.
: Line 1 is displayed in standard form.
: Cursor OFF
: Blink OFF
: Display OFF
: Extended register OFF
: Oscillating circuit OFF
: Power save OFF
: Voltage regulating circuit OFF
: Voltage follower OFF
: Boosting circuit OFF
: For built-in resistor
: 1/5 bias
: CGRAM not used
: Left shift
: Normal display
EPSON
10. Static icon blink control
As seen in MPU Interface, the RES pin inputs data at the
same timing as MPU resetting and performs initialization
concurrently with the MPU. However, if this pin is put
into the high impedance for a certain period after the
MPU bus and ports are reset, perform a reset input after
the input to the S1D12400 series is definitively set.
For the reset signal, it is necessary to input ‘0’ level
pulses at least for 10 s as described in DC Characteristics.
The ordinary operation will be started in 1 s or more
after the rising edge of the RES signal. When the RES pin
becomes active, each register will be cleared and set to
the above setup status.
If initialization is not executed by the RES pin when the
supply voltage is applied, a clear disable status may
appear.
In case the built-in liquid crystal power circuit is not
used, the RES input must be active when the external
liquid crystal power supply is turned on.
(SEGSA, B, C, D, E, F, G, H, I, J) =
(0,0,0,0,0,0,0,0,0,0): Display OFF
(SEGSA, B, C, D, E, F, G, H, I, J) =
(0,0,0,0,0,0,0,0,0,0): Blink OFF