BTS307 Infineon Technologies, BTS307 Datasheet - Page 4

no-image

BTS307

Manufacturer Part Number
BTS307
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of BTS307

Packages
P-TO220-5
Channels
1.0
Ron @ Tj = 25°c
250.0 mOhm
Recommended Operating Voltage Min.
5.8 V
Recommended Operating Voltage Max.
58.0 V
Il(sc)
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BTS307
Manufacturer:
infineon
Quantity:
5 510
Part Number:
BTS307
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
BTS307 E3062A
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
BTS307-E3043
Manufacturer:
SIEMENS
Quantity:
5 000
Part Number:
BTS307-E3062A
Manufacturer:
SIEMENS
Quantity:
4 000
Protection Functions
6
7
8
Semiconductor Group
Parameter and Conditions
at T
Initial peak short circuit current limit (pin 3 to 5)
Output clamp (inductive load switch off)
at V
Thermal overload trip temperature
Thermal hysteresis
Reverse battery (pin 3 to 1)
Diagnostic Characteristics
Open load detection current
Open load detection voltage
Short circuit detection voltage
Input and Status Feedback
Input resistance
Input turn-on threshold voltage
Input turn-off threshold voltage
Input threshold hysteresis
Off state input current (pin 2), V
On state input current (pin 2), V
Delay time for status with open load
Status output (open drain)
)
)
)
see circuit page 5
after Input neg. slope (see diagram page 10)
Zener limit voltage T
(included in standby current I
ST low voltage
(pin 3 to 5)
j
Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are not
designed for continuous repetitive operation.
Requires 150
diode has to be limited by the connected load. Note that the power dissipation is higher compared to normal
operating conditions due to the voltage drop across the intrinsic drain-source diode. The temperature
protection is not active during reverse current operation! Input and Status currents have to be limited (see
max. ratings page 2 and circuit page 6).
If a ground resistor R
OUT
= 25 °C, V
= V
bb
bb
- V
= 12 V unless otherwise specified
ON(CL)
resistor in GND connection. The reverse load current through the intrinsic drain-source
T
j
GND
=-40...+150°C, I
j
=-40...+150°C, I
6
)
is used, add the voltage drop across this resistor.
bb(off)
I
L
= 1 A, T
7
8
)
)
)
IN
IN
= 0.4 V
= 3.5? V
j
T
=-40..+150°C: V
ST
j
ST
=-40..150°C: V
T
= +1.6 mA:
j
= +1.6 mA:
T
=+150°C:
T
j
j
=-40°C:
=25°C:
4
t
I
T
-V
I
V
R
V
V
I
I
V
V
d(ST OL3)
Symbol
L(SCp)
L(off)
IN(off)
IN(on)
jt
T
ON(CL)
OUT(OL)
ON(SC)
IN(T+)
IN(T-)
ST(high)
ST(low)
I
V
bb
jt
IN(T)
150
min
4.0
2.4
0.8
5.4
59
10
--
--
--
--
--
--
--
--
--
--
1
1
Values
200
2.5
0.5
6.1
typ
10
10
20
25
--
--
--
--
--
--
--
--
--
6
3
max
2.5
0.4
BTS 307
2003-Oct-01
19
75
32
30
70
--
--
--
--
--
--
--
--
--
--
--
4
Unit
k
°C
A
V
K
V
A
V
V
V
V
V
A
A
V
s

Related parts for BTS307