Specifications of TMP86xy44UG

Package
QFP44
Rom Types (m=mask,p=otp,f=flash)
M/P
Rom Size
60
Ram Size
1K
Driver Led
19
Driver Lcd
-
Spi/sio Channels
1
Uart/sio Channels
1
I2c/sio Channels
-
High-speed Serial Output
-
Adc 8-bit Channels
-
Adc 10-bit Channels
8
Da Converter Channels
1
Timer Counter 18-bit Channel
-
Timer Counter 16-bit Channel
2
Timer Counter 8-bit Channel
2
Motor Channels
-
Watchdog Timer
Y
Dual Clock
Y
Clock Gear
-
Number Of I/o Ports
35
Power Supply (v)
4.5 to 5.5
AD Converted value Register 2
AD Converted value Register 1
AD Converter Control Register 2
ADCCR2
ADCDR1
ADCDR2
(001DH)
(001EH)
(001FH)
Note 1: Always set bit0 in ADCCR2 to "0" and set bit4 in ADCCR2 to "1".
Note 2: When a read instruction for ADCCR2, bit6 to 7 in ADCCR2 read in as undefined data.
Note 3: After STOP or SLOW/SLEEP mode are started, AD converter control register2 (ADCCR2) is all initialized and no data can
Table 13-1 ACK setting and Conversion time
Note 1: Setting for "−" in the above table are inhibited.
Note 2: Set conversion time setting should be kept more than the following time by Power supply voltage(VDD) .
ACK
Condition
000
001
010
011
100
101
110
111
-
-
be written in this register. Therfore, to use AD converter again, set the ADCCR2 newly after returning to NORMAL1 or
NORMAL2 mode.
VDD = 4.5 to 5.5 V
VDD = 2.7 to 5.5 V
AD09
AD01
IREFON
7
7
7
ACK
Conversion
1248/fc
156/fc
312/fc
624/fc
39/fc
78/fc
time
AD08
AD00
6
DA converter (Ladder resistor) connection
control
AD conversion time select
(Refer to the following table about the con-
version time)
6
6
IREFON
EOCF
16 MHz
AD07
19.5 μs
39.0 μs
78.0 μs
5
5
5
-
-
-
15.6 μs and more
31.2 μs and more
AD06
ADBF
"1"
4
156.0 μs
4
4
19.5 μs
39.0 μs
78.0 μs
8 MHz
-
-
AD05
Page 137
3
3
3
156.0 μs
fc: High Frequency oscillation clock [Hz]
19.5 μs
39.0 μs
78.0 μs
4 MHz
-
-
Reserved
Reserved
AD04
ACK
0:
1:
000:
001:
010:
011:
100:
101:
110:
111:
2
2
2
156.0 μs
Connected only during AD conversion
Always connected
39/fc
Reserved
78/fc
156/fc
312/fc
624/fc
1248/fc
Reserved
19.5 μs
39.0 μs
78.0 μs
2 MHz
-
-
AD03
1
1
1
124.8 μs
10 MHz
15.6 μs
31.2 μs
62.4 μs
AD02
"0"
0
0
0
-
-
(Initial value: **0* 000*)
(Initial value: 0000 0000)
(Initial value: 0000 ****)
124.8 μs
15.6 μs
31.2 μs
62.4 μs
5 MHz
-
-
TMP86CS44UG
124.8 μs
2.5 MHz
15.6 μs
31.2 μs
62.4 μs
-
-
R/W

Related parts for TMP86xy44UG