Specifications of 1-1600636-5

Product Series
XL
Connector Type
Connector Assembly
Termination Style
Panel
Mating Type
Blindmate
Guides
With
Mating Functionality
Mate First-Break Last
Voltage Rating (signal) (vac)
60
Voltage Rating (power) (vdc)
200
Sequencing
Yes
Connector Configuration Orientation
Right-to-Left
Centerline, Dc Module (mm [in])
6.35 [0.250]
Centerline, Matrix (mm [in])
2.54 x 2.54 [.100 x .100]
Contact Type
Socket
Connector Style
Receptacle
Housing Material
Thermoplastic - GF
Total Number Of Dc Power
8
Total Number Of Signal
24
Connector Contact Configuration (no. Of Pos./type)
4/DC Power, 24/Signal, 4/DC Power
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Application Use
Cable-to-Board
|
|
1.
1.1.
1.2.
1.3.
2.
2.1.
2.2.
3.
3.1.
3.2.
©2006 Tyco Electronics Corporation
Harrisburg, PA
All International Rights Reserved.
SCOPE
Content
This specification covers performance, tests and quality requirements for the Tyco Electronics Multi-
Beam XL* Cable Panel Mount and Squeeze-To-Release Receptacles.
Qualification
When tests are performed on the subject product line, procedures specified in Figure 3 shall be used.
All inspections shall be performed using the applicable inspection plan and product drawing.
Qualification Test Results
Successful qualification testing on the subject product line was completed on 02Dec04. The
Qualification Test Report number for this testing is 501-597. This documentation is on file at and
available from Engineering Practices and Standards (EPS).
Additional testing on part number 1874902-1 using 12 AWG wire on 3 adjacent contacts and .300 pitch
at 28 amperes was performed by TUV. The project number for this testing is S1600403-101.
APPLICABLE DOCUMENTS
The following documents form a part of this specification to the extent specified herein. Unless
otherwise specified, the latest edition of the document applies. In the event of conflict between the
requirements of this specification and the product drawing, the product drawing shall take precedence.
In the event of conflict between the requirements of this specification and the referenced documents,
this specification shall take precedence.
Tyco Electronics Documents
!
!
!
Industry Standard
EIA-364: Electrical Connector/Socket Test Procedures Including Environmental Classifications
REQUIREMENTS
Design and Construction
Product shall be of the design, construction and physical dimensions specified on the applicable
product drawing.
Materials
Materials used in the construction of this product shall be as specified on the applicable product
drawing.
109-197: Test Specification (AMP Test Specifications vs EIA and IEC Test Methods)
114-13112: Application Specification (Multi-Beam XL Cable Receptacle Assemblies)
501-597: Qualification Test Report (Multi-Beam XL* Cable Panel Mount and
Squeeze-To-Release Receptacles)
Product
Specification
Multi-Beam XL* Cable Panel Mount and Squeeze-To-Release
Receptacles
* Trademark
| Indicates change
For latest revision, visit our website at www.tycoelectronics.com\documents.
For Regional Customer Service, visit our website at www.tycoelectronics.com
108-2157
05Apr06 Rev C
1 of 9
LOC B

Related parts for 1-1600636-5

1-1600636-5 Summary of contents

Page 1

... Qualification Test Report number for this testing is 501-597. This documentation is on file at and available from Engineering Practices and Standards (EPS). | Additional testing on part number 1874902-1 using 12 AWG wire on 3 adjacent contacts and .300 pitch | at 28 amperes was performed by TUV. The project number for this testing is S1600403-101. ...

Page 2

... Adjacent Adjacent Adjacent Adjacent contacts Contacts Contacts Contacts --- 35 ----- ----- 28 --- --- --- --- --- Procedure EIA-364-18. Visual and dimensional ( inspection per product drawing. EIA-364-18. Visual inspection. EIA-364-23. Subject specimens to 100 milliamperes maximum and 20 millivolts maximum open circuit voltage ...

Page 3

... DC 500 megohms minimum for signal contacts. 1000 megohms minimum for power contacts. 1 minute hold with no breakdown or flashover maximum temperature rise at / specified current. MECHANICAL No discontinuities of 1 microsecond or longer duration. See Note. No discontinuities of 1 microsecond or longer duration. ...

Page 4

... Procedure EIA-364-13. Measure force necessary to unmate specimens at a maximum rate of 1 inch per minute. Size signal contacts 3 times using gage 1, then insert gage 2 and measure force necessary to separate. See Figure 5. EIA-364-5. Measure force necessary to insert contact into housing. EIA-364-29. Apply axial load to wire, as crimped to contacts ...

Page 5

... Clamp contacts as shown in Figure 6. EIA-364-32. Subject specimens to 36 cycles between -20 and 105 EIA-364-31, Method III, Condition B without cold shocks. Subject specimens to 10 cycles (10 days) between 25 and 95% RH. EIA-364-17, Method A, Test Condition 4. Subject mated specimens to 105 / for 504 hours (21 days). ...

Page 6

... Temperature life Mixed flowing gas Final examination of product (a) See paragraph 4.1.A. NOTE (b) Numbers indicate sequence in which tests are performed. (c) Energize at current for 18 (d) Precondition specimens with 5 durability cycles. (e) Power only in housing, signal with gage. (f) Precondition specimens with 50 durability cycles Rev C Test Group (a) ...

Page 7

... AWG wires). Test group 4 shall consist of 10 mated pairs (panel mount to right angle header and straight to vertical header, with 8 and 10 AWG wires). Test group 5 shall consist of a minimum of 11 mated pairs (panel mount to right angle header), 3 specimens with 10 AWG wires, 3 specimens with 14 AWG wires, and 5 specimens with 8 AWG wires ...

Page 8

... Tolerance: Unless otherwise specified, ±.005 or ± 2 degrees as applicable. NOTE 2. Material: AISI Type 02 tool steel per Material Specification 100-15. 3. Heat Treat: Rockwell C50-55 4. Gage surface shall be clean of contaminates or lubricants. Rev C Gage “A” Number Dimension 1 .0260 +.0000/-.0001 2 .0240 +.0001/-.0000 ...

Page 9

... Tolerance: Unless otherwise specified, ±.005 or ± 2 degrees as applicable. NOTE 2. Material: AISI Type 02 tool steel per Material Specification 100-15. 3. Heat Treat: Rockwell C50-55. Rev C Figure 6 Power Contact Tensile Test Clamp 108-2157 ...