ADP1650 Analog Devices, ADP1650 Datasheet - Page 22

no-image

ADP1650

Manufacturer Part Number
ADP1650
Description
1.5 A LED Flash Driver with I2C-Compatible Interface
Manufacturer
Analog Devices
Datasheet

Specifications of ADP1650

Product Description
1.5 A LED Flash Driver with I2C-Compatible Interface
Led #
1
Led Configuration
Serial
Topology
Inductive
Application
Flash
I2c Support
Yes
Max Iout (ma)
1500mA
Brightness Control
I2C
Peak Efficiency (%)
90%
Switching Frequency
3MHz
Over Volt Protection (v)
5.5V
Vin Min (v)
2.7V
Vout (v)
4.575 to 5.425
Synchronous
Yes
Package
12-Bump WLCSP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADP1650ACBZ-R7
Manufacturer:
WLCSP
Quantity:
6 535
Part Number:
ADP1650ACBZ-R7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADP1650
Table 12. Output Mode Register (Register 0x04)
Bit Name
IL_PEAK
STR_LV
FREQ_FB
OUTPUT_EN
STR_MODE
LED_MOD
Table 13. Fault Information Register (Register 0x05)
Bit Name
FL_OVP
FL_SC
FL_OT
FL_TO
FL_TX1
FL_IO2
FL_IL
FL_IDC
Bit
[7:6]
5
4
3
2
[1:0]
Bit
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R
R
R
R
Description
Inductor peak current limit setting
00 = 1.75 A
01 = 2.25 A
10 = 2.75 A (default)
11 = 3.0 A
0 = edge sensitive
1 = level sensitive (default)
0 = frequency foldback to 1.5 MHz not allowed (default)
1 = frequency foldback to 1.5 MHz allowed
0 = output off (default)
1 = output on
0 = software strobe mode (software flash occurs when output is enabled in flash mode)
1 = hardware strobe mode (the STROBE pin must go high for flash) (default)
Configures LED output mode
00 = standby mode (default)
01 = voltage output mode, VOUT = 5 V
10 = assist light mode
11 = flash mode
0 = no fault (default)
0 = no TxMASK1 operation mode during last flash (default)
0 = programmed dc current limit not hit (default)
Description
1 = overvoltage fault
0 = no fault (default)
1 = short-circuit fault
0 = no fault (default)
1 = overtemperature fault
0 = no fault (default)
1 = timeout fault
1 = TxMASK1 operational mode occurred during last flash
If GPIO2 is configured as TxMASK2
0 = no TxMASK2 operations mode during last flash (default)
1 = TxMASK2 operational mode occurred during last flash
If GPIO2 is configured as ILED
0 = no fault (default)
1 = indicator LED fault
0 = no fault (default)
1 = inductor peak current limit fault
1 = programmed dc current limit hit
Rev. C | Page 22 of 32