AD7680 Analog Devices, AD7680 Datasheet - Page 14

no-image

AD7680

Manufacturer Part Number
AD7680
Description
Manufacturer
Analog Devices
Datasheet

Specifications of AD7680

Resolution (bits)
16bit
# Chan
1
Sample Rate
100kSPS
Interface
Ser,SPI
Analog Input Type
SE-Uni
Ain Range
Uni Vdd
Adc Architecture
SAR
Pkg Type
SOP,SOT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7680ARMZ
Quantity:
40
Part Number:
AD7680BRMZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
AD7680
MODES OF OPERATION
The mode of operation of the AD7680 is selected by controlling
the (logic) state of the CS signal during a conversion. There are
two possible modes of operation, normal and power-down. The
point at which CS is pulled high after the conversion has been
initiated determines whether or not the AD7680 enters power-
down mode. Similarly, if the AD7680 is already in power-down,
CS can control whether the device returns to normal operation
or remains in power-down. These modes of operation are
designed to provide flexible power management options. These
options can optimize the power dissipation/throughput rate
ratio for differing application requirements.
NORMAL MODE
This mode provides the fastest throughput rate performance,
because the user does not have to worry about the power-up
times with the AD7680 remaining fully powered all the time.
Figure 16 shows the general diagram of the operation of the
AD7680 in this mode.
SDATA
SCLK
CS
1
4 LEADING ZEROS + CONVERSION RESULT
Figure 16. Normal Mode Operation
Rev. A | Page 14 of 24
The conversion is initiated on the falling edge of CS as described
in the
fully powered up at all times,
10 SCLK falling edges have elapsed after the falling edge of CS .
If CS is brought high any time after the 10th SCLK falling edge,
but before the 20th SCLK falling edge, the part remains
powered up, but the conversion is terminated and SDATA goes
back into three-state. At least 20 serial clock cycles are required
to complete the conversion and access the complete conversion
result. In addition, a total of 24 SCLK cycles accesses four
trailing zeros. CS may idle high until the next conversion or
may idle low until CS returns high sometime prior to the next
conversion, effectively idling CS low.
Once a data transfer is complete (SDATA has returned to three-
state), another conversion can be initiated after the quiet time,
t
10
QUIET
, has elapsed by bringing CS low again.
Serial Interface
20
section. To ensure that the part remains
CS must remain low until at least