AT80C51RD2 Atmel Corporation, AT80C51RD2 Datasheet - Page 25

no-image

AT80C51RD2

Manufacturer Part Number
AT80C51RD2
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT80C51RD2

Max. Operating Frequency
60 MHz
Cpu
8051-12C
Max I/o Pins
32
Spi
1
Uart
1
Sram (kbytes)
1.25
Operating Voltage (vcc)
2.7 to 5.5
Timers
4
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT80C51RD2-RLRUM
Manufacturer:
NXP
Quantity:
8 243
Part Number:
AT80C51RD2-RLRUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT80C51RD2-RLTIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT80C51RD2-RLTUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT80C51RD2-SLRUM
Manufacturer:
Atmel
Quantity:
967
Part Number:
AT80C51RD2-SLRUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT80C51RD2-SLSIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT80C51RD2-SLSUM
Manufacturer:
Atmel
Quantity:
1 445
Part Number:
AT80C51RD2-UM
Manufacturer:
FAIRCHIL
Quantity:
550
4113D–8051–01/09
Table 10-2.
CCON - PCA Counter Control Register (D8h)
Reset Value = 000X 0000b
Not bit addressable
The watchdog timer function is implemented in module 4 (see Figure 10-4).
The PCA interrupt system is shown in Figure 10-2.
• Bits 0 through 4 are the flags for the modules (bit 0 for module 0, bit 1 for module 1, etc.) and
Number
are set by hardware when either a match or a capture occurs. These flags can only be
cleared by software.
CF
Bit
7
7
6
5
4
3
2
1
0
Mnemonic
CCON Register
CCF4
CCF3
CCF2
CCF1
CCF0
CR
CR
Bit
CF
6
-
Description
PCA Counter Overflow flag
Set by hardware when the counter rolls over. CF flags an interrupt if bit ECF in CMOD is
set. CF may be set by either hardware or software but can only be cleared by software.
PCA Counter Run control bit
Must be cleared by software to turn the PCA counter off.
Set by software to turn the PCA counter on.
Reserved
The value read from this bit is indeterminate. Do not set this bit.
PCA Module 4 interrupt flag
Must be cleared by software.
Set by hardware when a match or capture occurs.
PCA Module 3 interrupt flag
Must be cleared by software.
Set by hardware when a match or capture occurs.
PCA Module 2 interrupt flag
Must be cleared by software.
Set by hardware when a match or capture occurs.
PCA Module 1 interrupt flag
Must be cleared by software.
Set by hardware when a match or capture occurs.
PCA Module 0 interrupt flag
Must be cleared by software.
Set by hardware when a match or capture occurs.
5
-
CCF4
4
CCF3
3
CCF2
2
AT80C51RD2
CCF1
1
CCF0
0
25