BXB150-48S05FLTJ Astec Power, BXB150-48S05FLTJ Datasheet

no-image

BXB150-48S05FLTJ

Manufacturer Part Number
BXB150-48S05FLTJ
Description
Manufacturer
Astec Power
Datasheet
BXB150 Series
Single output
Special Features
• Industry standard footprint
• Input voltage to ETS300-132-2
• Adjustable output voltage
• No minimum load required
• Separate case ground pin
• 2:1 input range for battery
• Undervoltage lockout (UVLO)
• UL, VDE and CSA
• Available RoHS compliant
• 2 year warranty
Safety
VDE0805/EN60950/IEC950
UL1950
CSA C22.2 No. 950
Total Power:
Input Voltage: 18 - 36 Vdc
# of Outputs:
MTBF >1.4 million hours
(Bellcore 332)
powered applications
safety approvals
150 W
36 - 75 Vdc
Single
Electrical Specifications
Output
Voltage adjustability:
Setpoint accuracy:
Line regulation
Load regulation
Minimum load
Overshoot
Undershoot
Ripple and noise
5 Hz - 20 MHz (see note 1)
Temperature coefficient
Transient response (see note 2)
Remote sense
Low line to high line
Full load to min. load
At turn on and turn-off
3.3 V and 5 V
12V and 15 V
Embedded Power for
Business-Critical Continuity
line drop compensation
±2.0% max. deviation
0.5 Vdc transmission
to within ±1.0%
170 μsrecovery
100 mV pk-pk,
75 mV pk-pk,
60% to 110%
±0.01% / ºC
20 mV rms
30 mV rms
±0.10%
±1.0%
±0.5%
None
None
0 %
Rev.05.13.08
bxb150
1 of 4

Related parts for BXB150-48S05FLTJ

BXB150-48S05FLTJ Summary of contents

Page 1

... BXB150 Series Single output Total Power: 150 W Input Voltage Vdc Vdc # of Outputs: Single Special Features • Industry standard footprint MTBF >1.4 million hours (Bellcore 332) • Input voltage to ETS300-132-2 • Adjustable output voltage • No minimum load required • Separate case ground pin • ...

Page 2

... G rms (approx.) Continuous, automatic recovery Non-latching Non-latching 110 °C baseplate, automataic recovery Embedded Power for Business-Critical Continuity Telecom Specifications Central office ETS300-132-2 interface A Rev.05.13.08 bxb150 ...

Page 3

... Tolerance : x.xx 0.02in. (0.51mm) x.xxx 0.010in. (0.254mm) Embedded Power for Business-Critical Continuity Regulation Model Number Line Load ±0.05% ±0.1% BXB150-24S3V3FLTJ ±0.05% ±0.1% BXB150-48S3V3FLTJ ±0.05% ±0.1% BXB150-48S05FLTJ ±0.05% ±0.1% BXB150-48S12FLTJ ±0.05% ±0.1% BXB150-48S15FLTJ Pin connections Pin Number Function 1 +Vin 2 Remote ON/OFF 8 3 Case ...

Page 4

... Embedded Power for Business-Critical Continuity Rev.05.13.08 Americas bxb150 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 ...

Related keywords