ST1284-02 STMicroelectronics, ST1284-02 Datasheet

no-image

ST1284-02

Manufacturer Part Number
ST1284-02
Description
PARALLEL PORT SINGLE TERMINATION NETWORK WITH ?15kV ESD PROTECTION
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST1284-02
Quantity:
524
Part Number:
ST1284-02
Manufacturer:
ST
0
Part Number:
ST1284-02
Manufacturer:
ST
Quantity:
20 000
Part Number:
ST1284-02-BUX
Manufacturer:
ST
0
Part Number:
ST1284-02A8
Manufacturer:
ST
0
Company:
Part Number:
ST1284-02A8
Quantity:
4 000
Part Number:
ST1284-02A8RL
Manufacturer:
SILICON
Quantity:
165
Part Number:
ST1284-02A8RL
Manufacturer:
ST
Quantity:
5 500
Part Number:
ST1284-02A8RL
Manufacturer:
ST/PBF
Quantity:
2 200
Part Number:
ST1284-02A8RL
Manufacturer:
ST
Quantity:
20 000
FEATURES
COMPLIES WITH THE FOLLOWING ESD
STANDARDS :
- IEC61000-4-2
- MIL STD 883E - Method 3015-7 : Class 3
(human body model).
MAIN APPLICATIONS
ECP/EPP Parallel Port termination on:
DESCRIPTION
The ST1284-xxA8/T8 is a highly integrated termi-
nation for enhanced high speed parallel ports. The
integrated termination complies to the IEEE1284
Standard recommendations and government
EMC compatibility requirements. It is built around
two basic cells. The first one (Cell 1) provides line
termination, EMI filtering and ESD protection for
the Strobe and Datalines while the second one
(Cell 2) provides EMI filtering and ESD protection
for the Control and Status lines. In addition,
ST1284-xxA8 provides extra protection against
ESD. When tested according to IEC61000-4-2,
they withstand ±8kV contact discharges and
±15kV air-discharges, thereby providing to the
system the necessary robustness to meet up to
level 4 of IEC61000-4-2, without the need for addi-
tional ESD protection components. Cells 1 and 2
are described in more detail in figures 1 and 2.
July 2002 - Ed: 1B
Desktops
Notebooks
Workstations
Servers
PC Peripherals
Set Top Box
One device for parallel port termination
Compliant with IEEE1284 standard
EMI / RFI noise filtering
Highly integrated solution in 28 pin QSOP and
TSSOP packages
One single device provides the proper termina-
tion for 8 datalines, 1 strobe line, 4 control lines
and 4 statuts lines
In system ESD protection of ±15 kV (air dis-
charge) as per IEC61000-4-2 level 4
A.S.D.
®
TM
±15kV (air discharge)
± 8kV
(contact discharge)
NETWORK WITH ±15kV ESD PROTECTION
PARALLEL PORT SINGLE TERMINATION
SCHEMATIC DIAGRAM
Code 01
Code 02
Code 03
Tolerance
10
11
12
13
14
1
2
3
4
5
6
7
8
9
Rs
C
Vcc
R1
Vcc
Vcc
Vcc
Vcc
Rs
R2
R1
R2
R2
C
C
C
C
± 10%
4.7k
2.2k
C
1k
QSOP28 / TSSOP28
ST1284-xxA8/T8
R1
Vcc
R1
Rs
Rs
C
Rs
C
C
Vcc
R1
Vcc
R1
Vcc
Vcc
R1
R1
± 10%
C
4.7k
2.2k
5.1k
R2
Rs
Rs
C
C
R1
C
Vcc
R1
Vcc
R1
Vcc
± 10%
Rs
Rs
33
33
39
C
C
Rs
Vcc
R1
Vcc
R1
R2
C
C
Vcc
Vcc
R2
Vcc
Gnd
± 20%
180pF
220pF
150pF
C
28
27
26
25
24
23
22
21
20
19
18
17
16
15
1/7

Related parts for ST1284-02

ST1284-02 Summary of contents

Page 1

... In system ESD protection of ±15 kV (air dis- charge) as per IEC61000-4-2 level 4 DESCRIPTION The ST1284-xxA8/ highly integrated termi- nation for enhanced high speed parallel ports. The integrated termination complies to the IEEE1284 Standard recommendations and government EMC compatibility requirements built around two basic cells ...

Page 2

... Forward voltage drop F BASIC CELL CONFIGURATIONS The ST1284-xxA8/T8 is built around the two basic cells described below which integrate the recom- mended IEEE1284 network and the ESD protection compatible with IEC61000-4-2 level 4 Fig. 1:Cell 1 for line termination, EMI filtering and ESD protection for the Datalines and Strobe sig- nals ...

Page 3

... APPLICATION INFORMATION The functional diagram here above presents a IEEE1284-A connector pinout and show how to connect the ST1284-xxA8/T8 in order to correctly terminate and filter the 17 signal lines. The IEEE1284-A con- nector is the PC standard for the host connection. Control and status lines (from 10 to 17) only require a pull-up resistor (Rp) and a filter capacitor (C). ...

Page 4

... ESD susceptibility. This test is described in the IEC61000-4-2 and is already in place in Europe. This test requires that a device tolerates ESD events and remain operational without user intervention. The ST1284-xxA8/T8 is particularly optimized to perform ESD protection. ESD protection is based on the use of device which clamps at : This protection function is splitted in 2 stages ...

Page 5

... Voutput clamping voltage very close to V Fig. A4: Measurement conditions ESD SURGE ST1284 Vinput Fig. A5: Remaining voltage at the input and output of the device during a ±16kV ESD surge (IEC61000-4-2 Vinput Vinput . . Voutput R t =8kV, Rg=330 (IEC61000-4-2 standard (positive strike) and -V BR Voutput ST1284-xxA8/T8 =7V (typ.) BR (negative strike) F 5/7 ...

Page 6

... ST1284-xxA8/T8 PACKAGE MECHANICAL DATA QSOP28 (Plastic PACKAGE MECHANICAL DATA TSSOP28 (Plastic) A2 aaa 6/7 REF REF aaa DIMENSIONS Millimeters Inches Min. Max. Min. 1.55 1.75 0.061 0.10 0.25 0.004 0.20 0.30 0.008 0.18 0.25 0.007 9.80 9.98 0.386 5.79 6.20 0.228 0.64 typ. ...

Page 7

... ST1284-02 ST1284-03A8RL ST1284-03 ST1284-01T8RL ST1284-01 ST1284-02T8RL ST1284-02 ST1284-03T8RL ST1284-03 Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of STMicroelectronics ...

Related keywords