TDA7567PD STMicroelectronics, TDA7567PD Datasheet - Page 15

no-image

TDA7567PD

Manufacturer Part Number
TDA7567PD
Description
IC AMP QUAD BCD/BRIDG POWERSO36
Manufacturer
STMicroelectronics
Type
Class SBr
Datasheet

Specifications of TDA7567PD

Output Type
4-Channel (Quad)
Max Output Power X Channels @ Load
75W x 4 @ 2 Ohm
Voltage - Supply
8 V ~ 18 V
Features
Differential Inputs, I²C, Mute, Short-Circuit and Thermal Protection, Standby
Mounting Type
Surface Mount
Package / Case
PowerSO-36 Exposed Top Pad
Operational Class
Class-AB
Audio Amplifier Output Configuration
4-Channel Stereo
Audio Amplifier Function
Speaker
Single Supply Voltage (typ)
14.4V
Dual Supply Voltage (typ)
Not RequiredV
Power Supply Requirement
Single
Power Dissipation
85W
Rail/rail I/o Type
No
Single Supply Voltage (min)
8V
Single Supply Voltage (max)
18V
Dual Supply Voltage (min)
Not RequiredV
Dual Supply Voltage (max)
Not RequiredV
Operating Temp Range
-55C to 150C
Operating Temperature Classification
Military
Mounting
Surface Mount
Pin Count
36
Package Type
PowerSO SLUG UP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TDA7567PD
Manufacturer:
ST
0
TDA7567PD
3.3
3.4
Output DC offset detection
Any DC output offset exceeding ±2 V are signalled out. This inconvenient might occur as a
consequence of initially defective or aged and worn-out input capacitors feeding a DC
component to the inputs, so putting the speakers at risk of overheating.
This diagnostic has to be performed with low-level output AC signal (or V
The test is run with selectable time duration by microprocessor (from a "start" to a "stop"
command):
Excess offset is signalled out if persistent throughout the assigned testing time. This feature
is disabled if any overloads leading to activation of the short-circuit protection occurs in the
process.
AC diagnostic
It is targeted at detecting accidental disconnection of tweeters in 2-way speaker and, more
in general, presence of capacitively (AC) coupled loads.
This diagnostic is based on the notion that the overall speaker's impedance (woofer +
parallel tweeter) will tend to increase towards high frequencies if the tweeter gets
disconnected, because the remaining speaker (woofer) would be out of its operating range
(high impedance). The diagnostic decision is made according to peak output current
thresholds, and it is enabled by setting (IB2-D2) = 1.
Two different detection levels are available:
To correctly implement this feature, it is necessary to briefly provide a signal tone (with the
amplifier in "play") whose frequency and magnitude are such to determine an output current
higher than 500 mApk with IB2(D7)=0 (higher than 250 mApk with IB2(D7)=1) in normal
conditions and lower than 250 mApk with IB2(D7)=0 (lower than 125 mApk with IB2(D7)=1)
should the parallel tweeter be missing.
The test has to last for a minimum number of 3 sine cycles starting from the activation of the
AC diagnostic function IB2<D2>) up to the I
confirm presence of tweeter, it is necessary to find at least 3 current pulses over the above
thresholds over all the measuring period, else an "open tweeter" message will be issued.
The frequency / magnitude setting of the test tone depends on the impedance
characteristics of each specific speaker being used, with or without the tweeter connected
(to be calculated case by case). High-frequency tones (> 10 kHz) or even ultrasonic signals
are recommended for their negligible acoustic impact and also to maximize the impedance
module's ratio between with tweeter-on and tweeter-off.
High current threshold IB2 (D7) = 0
Low current threshold IB2 (D7) = 1
START = Last reading operation or setting IB1 - D5 - (OFFSET enable) to 1
STOP = Actual reading operation
Iout > 500 mApk = NORMAL STATUS
Iout < 300 mApk = OPEN TWEETER
Iout > 250 mApk = NORMAL STATUS
Iout < 125 mApk = OPEN TWEETER
Doc ID 16903 Rev 1