TDA7563B STMicroelectronics, TDA7563B Datasheet - Page 19

no-image

TDA7563B

Manufacturer Part Number
TDA7563B
Description
IC AMP QUAD MULTIFUNC FLEXIWATT2
Manufacturer
STMicroelectronics
Type
Class ABr
Datasheet

Specifications of TDA7563B

Output Type
4-Channel (Quad)
Max Output Power X Channels @ Load
75W x 4 @ 2 Ohm
Voltage - Supply
8 V ~ 18 V
Features
I²C, Mute, Short-Circuit and Thermal Protection, Standby
Mounting Type
Through Hole
Package / Case
27-Flexiwatt (bent and staggered leads)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TDA7563B
Manufacturer:
ST
0
Part Number:
TDA7563B
Manufacturer:
ST
Quantity:
20 000
Part Number:
TDA7563B DD
Manufacturer:
ST
0
Part Number:
TDA7563B DD
Manufacturer:
ST
Quantity:
20 000
Part Number:
TDA7563B-DB
Manufacturer:
ST
Quantity:
20 000
Part Number:
TDA7563B-DD
Manufacturer:
ST
0
Part Number:
TDA7563B-DD
Manufacturer:
ST
Quantity:
20 000
Part Number:
TDA7563B/TDA7563
Manufacturer:
ST
0
Part Number:
TDA7563B@@@@@
Manufacturer:
ST
0
Part Number:
TDA7563BH
Manufacturer:
FREESCALE
Quantity:
150
Part Number:
TDA7563BH
Manufacturer:
ST
Quantity:
20 000
TDA7563B
5
5.1
Multiple faults
When more misconnections are simultaneously in place at the audio outputs, it is
guaranteed that at least one of them is initially read out. The others are notified after
successive cycles of I
This is true for both kinds of diagnostic (Turn on and Permanent).
The table below shows all the couples of double-fault possible. It should be taken into
account that a short circuit with the 4 ohm speaker unconnected is considered as double
fault.
Table 5.
S. GND (so) / S. GND (sk) in the above table make a distinction according to which of the 2
outputs is shorted to ground (test-current source side= so, test-current sink side = sk). More
precisely, in Channels LF and RR, so = CH+, sk = CH-; in Channels LR and RF, so = CH-, sk
= CH+.
In permanent diagnostic the table is the same, with only a difference concerning open load
(*), which is not among the recognizable faults. Should an open load be present during the
device's normal working, it would be detected at a subsequent Turn on Diagnostic cycle (i.e.
at the successive car radio turn-on).
Faults availability
All the results coming from I
measurements inside a defined period of time. If the fault is stable throughout the whole
period, it will be sent out.
To guarantee always resident functions, every kind of diagnostic cycles (turn-on, permanent,
offset) will be reactivate after any I
new cycle will be able to start, but the read data will come from the previous diag. cycle (i.e.
The device is in turn-on state, with a short to GND, then the short is removed and micro
reads I
cycle. If another I
to observe a change in diagnostic bytes, two I
S. Across L.
S. GND (so)
S. GND (sk)
Open L.
S. Vs
2
-
C. The short to GND is still present in bytes, because it is the result of the previous
Double fault table for turn on diagnostic
S. GND (so)
2
C reading operation occurs, the bytes do not show the short). In general
S. GND
2
C reading and faults removal, provided that the diagnostic is enabled.
/
/
/
/
2
C bus, by read operations, are the consequence of
Doc ID 12733 Rev 3
S. GND (sk)
2
S. GND
S. GND
C reading operation. So, when the micro reads the I
/
/
/
2
C reading operations are necessary.
S. Vs + S.
S. Vs
S. Vs
S. Vs
GND
/
/
S. Across L.
S. Across L.
S. GND
S. GND
S. Vs
/
Multiple faults
Open L. (*)
Open L. (*)
Open L.
S. GND
S. Vs
N.A.
2
19/33
C, a