XPSAK351144P Crouzet USA, XPSAK351144P Datasheet - Page 40

80C6923

XPSAK351144P

Manufacturer Part Number
XPSAK351144P
Description
80C6923
Manufacturer
Crouzet USA
Datasheet

Specifications of XPSAK351144P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3PST-NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
45mm
Rohs Compliant
Yes
Description
1
3
4
2
8
1
2
7
5
6
3 4
6
10
7
8
9
5
Safety automation system solutions
Preventa™ safety PLCs
Modular, XPSMF60
Rack, power supply and CPU
Modular assembly consisting of:
1 A metal rack XPSMFGEH01.
2 A c 24 V power supply module XPSMFPS01.
3 A central processing unit XPSMFCPU22.
4 Six optional “in rack” I/O cards (back plane bus assures the electrical connection
5 A metal plate for securing shielded analog input connection cables (EMC),
6 One ground connection screw.
7 Two cooling fans (beneath the metal rack).
8 Four Ø 0.55 in (14 mm) elongated holes for mounting the rack on a vertical
Power supply module XPSMFPS01 and Central processing unit XPSMFCPU22
consisting of:
1 Four voltage status LEDs (FAULT, 24 V, 3.3 V or 5 V).
2 A RESTART button (accessible using fine pointed tool).
3 A 3-pole terminal block (3 captive screws) for “Fault contact” function
4 A c 24 V supply terminal block, including ground connection
5 A grip to assist installation/removal of the power supply module.
6 Seven process status LEDs.
7 Four integrated RJ45 (type 10BASE-T/100BASE-TX) switched ports for
8 Two process status LEDs.
9 A SUB-D 9-pin connector (FB2) for connection on Modbus® serial (RTU) (FB1 not
10 A grip to assist installation/removal of the CPU.
(1) “Fault contact” function: the power supply module incorporates a volt-free changeover
contact. Operating errors occurring in the system are read and displayed by the LEDs. The errors
are analyzed on the programming PC:
(2) Removable screw terminal blocks are provided with the power supply and “in rack” I/O cards.
01
02
03 FAULT
Description
Modular safety PLC
of “in rack” cards installed, the power supply module and the CPU).
support.
Programming, and for Safety and non-safety related communication on Ethernet.
(safety related using SafeEthernet protocol and Non-safety related using
Modbus® TCP server protocol).
used), with process status LED.
Contact positions
1-2 closed (2-3 open)
1-2 open (2-3 closed)
Status
Normal operation of the PLC.
Absence of supply to the PLC or the CPU is in
ERROR STOP mode.
(2)
.
(1)
.
2/39
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9

Related parts for XPSAK351144P