XPSAK351144P Crouzet USA, XPSAK351144P Datasheet - Page 104

80C6923

XPSAK351144P

Manufacturer Part Number
XPSAK351144P
Description
80C6923
Manufacturer
Crouzet USA
Datasheet

Specifications of XPSAK351144P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3PST-NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
45mm
Rohs Compliant
Yes
Connections (continued)
1 10/100BaseT 10/100BaseT 2
Connections
XPSMF3AIO8401
G
A2
L-
G
A1
L- L+ L+
24V DC
RUN
ERROR
PROG
FORCE
FAULT
OSL
BL
S1 I1+ I1- S2 I2+ I2-
AI
1 2 3 4 5 6
B
S3 I3+ I3- S4 I4+ I3-
AI
7 8 9 10 11 12
C
AI
S5 I5+ I5- S6 I6+ I6-
13 14 15 16 17 18
D
S7 I7+ I7- S8 I8+ I8-
AI
19 20 21 22 23 24
E
AO
1+ 1- 2+ 2- 3+ 3- 4+ 4-
25 26 27 28 29 30 31 32
F
Safety automation system solutions
Preventa™ safety PLCs
Compact and modular
Safety remote mixed I/O modules XPSMF3
A1
A2
B
C
D
E
F
G
Item
Item
Connection
Supply
Ground
Inputs - Analog
Inputs - Analog
Inputs - Analog
Inputs - Analog
Outputs - Analog
Connection
Programming
Safe Communication (all
XPSMF Safety PLCs and
Remote I/Os)
Screw N° Screw
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Integrated 2
RJ45 switched
Ethernet
Communication
ports
L+
L+
L-
L-
t
S1
I1+
I1-
S2
I2+
I2-
S3
I3+
I3-
S4
I4+
I4-
S5
I5+
I5-
S6
I6+
I6-
S7
I7+
I7-
S8
I8+
I8-
O1+
O1-
O2+
O2-
O3+
O3-
O4+
O4-
Function
c 24 V
c 24 V
c 24 V (reference pole)
c 24 V (reference pole)
Ground
Transmitter supply 1
Input 1
Reference pole
Transmitter supply 2
Input 2
Reference pole
Transmitter supply 3
Input 3
Reference pole
Transmitter supply 4
Input 4
Reference pole
Transmitter supply 5
Input 5
Reference pole
Transmitter supply 6
Input 4
Reference pole
Transmitter supply 7
Input 7
Reference pole
Transmitter supply 8
Input 8
Reference pole
Output 1
Output 1 reference pole
Output 2
Output 2 reference pole
Output 3
Output 3 reference pole
Output 4
Output 4 reference pole
Function
Either of the two switched Ethernet
ports can be used to create a
connection between the safety remote
I/O and the programming terminal in a
point to point or via an Ethernet
network for setting the IP address
Either of the two switched Ethernet
ports can be used to create a
connection between the safety PLC
and other safety related components
(e.g other XPSMF safety PLCs or
Safety Remote I/O modules) this can
be established in a point to point way
or via an Ethernet network.
2/103
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9

Related parts for XPSAK351144P