SC16C750IB64,151 NXP Semiconductors, SC16C750IB64,151 Datasheet - Page 21

IC UART SINGLE W/FIFO 64-LQFP

SC16C750IB64,151

Manufacturer Part Number
SC16C750IB64,151
Description
IC UART SINGLE W/FIFO 64-LQFP
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SC16C750IB64,151

Number Of Channels
1, UART
Fifo's
64 Byte
Voltage - Supply
2.5V, 3.3V, 5V
With Auto Flow Control
Yes
With False Start Bit Detection
Yes
With Modem Control
Yes
With Cmos
Yes
Mounting Type
Surface Mount
Package / Case
64-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
568-3287
935270054151
SC16C750IB64-S

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16C750IB64,151
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Philips Semiconductors
9397 750 11623
Product data
7.4 Interrupt Status Register (ISR)
The SC16C750 provides six levels of prioritized interrupts to minimize external
software interaction. The Interrupt Status Register (ISR) provides the user with six
interrupt status bits. Performing a read cycle on the ISR will provide the user with the
highest pending interrupt level to be serviced. No other interrupts are acknowledged
until the pending interrupt is serviced. Whenever the interrupt status register is read,
the interrupt status is cleared. However, it should be noted that only the current
pending interrupt is cleared by the read. A lower level interrupt may be seen after
re-reading the interrupt status bits.
(bits 0-5) for the six prioritized interrupt levels and the interrupt sources associated
with each of these interrupt levels.
Table 12:
Table 13:
Priority
level
1
2
2
3
4
Bit
7-6
5
4
3-1
0
Interrupt source
Interrupt Status Register bits description
ISR[3]
0
0
1
0
0
Symbol
ISR[7-6]
ISR[5]
ISR[4]
ISR[3-1]
ISR[0]
Rev. 04 — 20 June 2003
ISR[2]
1
1
1
0
0
Description
FIFOs enabled. These bits are set to a logic 0 when the FIFO is
not being used. They are set to a logic 1 when the FIFOs are
enabled.
64-byte FIFO enable.
Not used.
INT priority bits 2-0. These bits indicate the source for a pending
interrupt at interrupt priority levels 1, 2, and 3 (see
INT status.
Logic 0 or cleared = default condition.
Logic 0 = 16-byte operation.
Logic 1 = 64-byte operation.
Logic 0 or cleared = default condition.
Logic 0 = An interrupt is pending and the ISR contents may be
used as a pointer to the appropriate interrupt service routine.
Logic 1 = No interrupt pending (normal default condition).
ISR[1]
1
0
0
1
0
Table 12 “Interrupt source”
ISR[0]
0
0
0
0
0
Source of the interrupt
LSR (Receiver Line Status Register)
RXRDY (Received Data Ready)
RXRDY (Receive Data time-out)
TXRDY (Transmitter Holding Register
Empty)
MSR (Modem Status Register)
© Koninklijke Philips Electronics N.V. 2003. All rights reserved.
UART with 64-byte FIFO
shows the data values
SC16C750
Table
12).
21 of 45

Related parts for SC16C750IB64,151