SC16C554BIB80,557 NXP Semiconductors, SC16C554BIB80,557 Datasheet - Page 19

IC UART QUAD SOT315-1

SC16C554BIB80,557

Manufacturer Part Number
SC16C554BIB80,557
Description
IC UART QUAD SOT315-1
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SC16C554BIB80,557

Number Of Channels
4, QUART
Package / Case
80-LQFP
Fifo's
16 Byte
Voltage - Supply
2.5V, 3.3V, 5V
With Auto Flow Control
Yes
With False Start Bit Detection
Yes
With Modem Control
Yes
With Cmos
Yes
Mounting Type
Surface Mount
Data Rate
5 Mbps
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.25 V
Supply Current
6 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Supply Voltage
2.5 V or 3.3 V or 5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
935274934557
SC16C554BIB80
SC16C554BIB80
NXP Semiconductors
SC16C554B_554DB
Product data sheet
Fig 10. CTS functional timing waveforms
Fig 11. RTS functional timing waveforms, RCV FIFO trigger level = 1 byte, 4 bytes, or 8 bytes
CTS
RTS
IOR
TX
RX
(1) When CTS is LOW, the transmitter keeps sending serial data out.
(2) If CTS goes HIGH before the middle of the last stop bit of the current byte, the transmitter finishes sending the current byte, but
(3) When CTS goes from HIGH to LOW, the transmitter begins sending data again.
(1) N = RCV FIFO trigger level (1 byte, 4 bytes, or 8 bytes).
(2) The two blocks in dashed lines cover the case where an additional byte is sent as described in
is does not send the next byte.
Start
6.4.3 Enabling autoflow control and auto-CTS
6.4.4 Auto-CTS and auto-RTS functional timing
Start
byte N
Remark: Auto-CTS is not supported in channel D of the HVQFN48 package, therefore
MCR[5] of channel D should not be written.
Autoflow control is enabled by setting MCR[5] and MCR[1].
Table 7.
bits 0 to 7
The receiver FIFO trigger level can be set to 1 byte, 4 bytes, 8 bytes, or 14 bytes. These
are described in
MCR[5]
1
1
0
Stop
Stop
Enabling autoflow control and auto-CTS
All information provided in this document is subject to legal disclaimers.
Figure 11
Start
5 V, 3.3 V and 2.5 V quad UART, 5 Mbit/s (max.) with 16-byte FIFOs
1
MCR[1]
1
0
X
Start
byte N + 1
Rev. 4 — 8 June 2010
and
2
bits 0 to 7
Figure
Stop
12.
Stop
Selection
auto RTS and CTS
auto CTS
disable
SC16C554B/554DB
N
N + 1
Section
Start
Start
6.4.1.
bits 0 to 7
© NXP B.V. 2010. All rights reserved.
byte
002aaa050
002aaa049
Stop
Stop
19 of 58

Related parts for SC16C554BIB80,557