SC16C752BIB48,157 NXP Semiconductors, SC16C752BIB48,157 Datasheet - Page 31

IC UART DUAL W/FIFO 48-LQFP

SC16C752BIB48,157

Manufacturer Part Number
SC16C752BIB48,157
Description
IC UART DUAL W/FIFO 48-LQFP
Manufacturer
NXP Semiconductors
Type
Dual UART with 64-byte FIFOsr
Datasheet

Specifications of SC16C752BIB48,157

Number Of Channels
2, DUART
Package / Case
48-LQFP
Fifo's
64 Byte
Voltage - Supply
2.5V, 3.3V, 5V
With Auto Flow Control
Yes
With False Start Bit Detection
Yes
With Modem Control
Yes
Mounting Type
Surface Mount
Data Rate
5 Mbps
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.25 V
Supply Current
4.5 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Supply Voltage
2.5 V or 3.3 V or 5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-1322
935274411157
SC16C752BIB48

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16C752BIB48,157
Manufacturer:
NXP Semiconductors
Quantity:
10 000
NXP Semiconductors
8. Programmer’s guide
SC16C752B
Product data sheet
The base set of registers that is used during high-speed data transfer have a
straightforward access method. The extended function registers require special access
bits to be decoded along with the address lines. The following guide will help with
programming these registers. Note that the descriptions below are for individual register
access. Some streamlining through interleaving can be obtained when programming all
the registers.
Table 23.
Command
Set baud rate to VALUE1, VALUE2
Set Xoff1, Xon1 to VALUE1, VALUE2
Set Xoff2, Xon2 to VALUE1, VALUE2
Set software flow control mode to VALUE
Set flow control threshold to VALUE
Register programming guide
All information provided in this document is subject to legal disclaimers.
5 V, 2.2 V and 2.5 V dual UART, 5 Mbit/s (max.), with 64-byte FIFOs
Rev. 6 — 30 November 2010
Actions
Read LCR (03h), save in temp
Read LCR (03h), save in temp
Read LCR (03h), save in temp
Read LCR (03h), save in temp
Read LCR (03h), save in temp1
Set LCR (03h) to 80h
Set DLL (00h) to VALUE1
SET DLM (01h) to VALUE2
Set LCR (03h) to temp
Set LCR (03h) to BFh
Set Xoff1 (06h) to VALUE1
SET Xon1 (04h) to VALUE2
Set LCR (03h) to temp
Set LCR (03h) to BFh
Set Xoff2 (07h) to VALUE1
SET Xon2 (05h) to VALUE2
Set LCR (03h) to temp
Set LCR (03h) to BFh
Set EFR (02h) to VALUE
Set LCR (03h) to temp
Set LCR (03h) to BFh
Read EFR (02h), save in temp2
Set EFR (02h) to 10h + temp2
Set LCR (03h) to 00h
Read MCR (04h), save in temp3
Set MCR (04h) to 40h + temp3
Set TCR (06h) to VALUE
Set MCR (04h) to temp3
Set LCR (03h) to BFh
Set EFR (02h) to temp2
Set LCR (03h) to temp1
SC16C752B
© NXP B.V. 2010. All rights reserved.
31 of 47