SC16IS760IPW,112 NXP Semiconductors, SC16IS760IPW,112 Datasheet - Page 12

no-image

SC16IS760IPW,112

Manufacturer Part Number
SC16IS760IPW,112
Description
IC UART 64BYTE 24TSSOP
Manufacturer
NXP Semiconductors
Type
IrDA or RS- 232 or RS- 485r
Datasheet

Specifications of SC16IS760IPW,112

Number Of Channels
1, UART
Package / Case
24-TSSOP (0.173", 4.40mm Width)
Features
Low Current
Fifo's
64 Byte
Protocol
RS232, RS485
Voltage - Supply
2.5V, 3.3V, 5V
With Auto Flow Control
Yes
With False Start Bit Detection
Yes
With Modem Control
Yes
Mounting Type
Surface Mount
Data Rate
5 Mbps
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.3 V
Supply Current
6 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Supply Voltage
2.5 V or 3.3 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
568-4000 - DEMO BOARD SPI/I2C TO DUAL UART568-3510 - DEMO BOARD SPI/I2C TO UART
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
568-4185
935279287112
SC16IS760IPW
SC16IS760IPW

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16IS760IPW,112
Manufacturer:
VISHAY
Quantity:
61 626
NXP Semiconductors
SC16IS740_750_760_6
Product data sheet
7.3.1 RX
7.3.2 TX
There are two other enhanced features relating to software flow control:
When software flow control operation is enabled, the SC16IS740/750/760 will compare
incoming data with Xoff1/Xoff2 programmed characters (in certain cases, Xoff1 and Xoff2
must be received sequentially). When the correct Xoff characters are received,
transmission is halted after completing transmission of the current character. Xoff
detection also sets IIR[4] (if enabled via IER[5]) and causes IRQ to go LOW.
To resume transmission, an Xon1/Xon2 character must be received (in certain cases
Xon1 and Xon2 must be received sequentially). When the correct Xon characters are
received, IIR[4] is cleared, and the Xoff interrupt disappears.
Xoff1/Xoff2 character is transmitted when the RX FIFO has passed the HALT trigger level
programmed in TCR[3:0] or the selectable trigger level in FCR[7:6]
Xon1/Xoff2 character is transmitted when the RX FIFO reaches the RESUME trigger level
programmed in TCR[7:4] or RX FIFO falls below the lower selectable trigger level in
FCR[7:6].
The transmission of Xoff/Xon(s) follows the exact same protocol as transmission of an
ordinary character from the FIFO. This means that even if the word length is set to be 5, 6,
or 7 bits, then the 5, 6, or 7 least significant bits of XOFF1/XOFF2 or XON1/XON2 will be
transmitted. (Note that the transmission of 5, 6, or 7 bits of a character is seldom done, but
this functionality is included to maintain compatibility with earlier designs.)
It is assumed that software flow control and hardware flow control will never be enabled
simultaneously.
Xon Any function (MCR[5]): Receiving any character will resume operation after
recognizing the Xoff character. It is possible that an Xon1 character is recognized as
an Xon Any character, which could cause an Xon2 character to be written to the RX
FIFO.
Special character (EFR[5]): Incoming data is compared to Xoff2. Detection of the
special character sets the Xoff interrupt (IIR[4]) but does not halt transmission. The
Xoff interrupt is cleared by a read of the IIR. The special character is transferred to the
RX FIFO.
Figure 11
Single UART with I
Rev. 06 — 13 May 2008
shows an example of software flow control.
2
C-bus/SPI interface, 64-byte FIFOs, IrDA SIR
SC16IS740/750/760
© NXP B.V. 2008. All rights reserved.
12 of 62

Related parts for SC16IS760IPW,112