PEB 3086 H V1.4 Infineon Technologies, PEB 3086 H V1.4 Datasheet - Page 51

no-image

PEB 3086 H V1.4

Manufacturer Part Number
PEB 3086 H V1.4
Description
IC ISDN ACCESS CTRLR TQFP64
Manufacturer
Infineon Technologies
Series
ISAC™r
Datasheet

Specifications of PEB 3086 H V1.4

Function
Subscriber Access Controller
Interface
HDLC, IOM-2, ISDN, Parallel, SCI
Number Of Circuits
1
Voltage - Supply
3.3V
Current - Supply
30mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
64-LFQFP
Includes
D-Channel Access Control and Priority Handler, Monitor Channel Handler, Non-Auto Mode, Transparent Mode
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEB3086HV1.4X
PEB3086HV14XP
SP000007567
ISAC-SX
PEB 3086
Description of Functional Blocks
TE Mode
After multiframe synchronization has been established, the Q data will be inserted at the
upstream (TE ® NT) F
bit position in each 5th S/T frame (see
Table
8).
A
When synchronization is not achieved or lost, each received F
bit is mirrored to the next
A
transmitted F
bit.
A
Multiframe synchronization is achieved after two complete multiframes have been
detected with reference to F
/N bit and M bit positions. Multiframe synchronization is lost
A
if bit errors in F
/N bit or M bit positions have been detected in two consecutive
A
multiframes. The synchronization state is indicated by the MSYN bit in the S/Q-channel
receive register (SQRR1).
The multiframe synchronization can be enabled or disabled by programming the MFEN
bit in the S/Q-channel transmit register (SQXR1).
NT Mode
The transceiver in NT mode starts multiframing if SQXR1.MFEN is set.
After multiframe synchronization has been established in the TE, the Q data will be
inserted at the upstream (TE ® NT) F
bit position by the TE in each 5th S/T frame, the
A
S data will be inserted at the downstream (NT ® TE) S bit position in each S/T frame
(see
Table
8).
Interrupt Handling for Multiframing
To trigger the microcontroller for a multiframe access an interrupt can be generated once
per multiframe (SQW) or if the received S-channels (TE) or Q-channel (NT) have
changed (SQC).
In both cases the microcontroller has access to the multiframe within the duration of one
multiframe (5 ms).
Data Sheet
51
2003-01-30

Related parts for PEB 3086 H V1.4