TS190PTR Clare, TS190PTR Datasheet
TS190PTR
Specifications of TS190PTR
Available stocks
Related parts for TS190PTR
TS190PTR Summary of contents
Page 1
... BS EN 60950:1992 (BS7002:1992) • Certificate #: 7344 • 41003:1993 Certificate #: 7344 Ordering Information Part # Description TS190 8 Pin DIP (50/Tube) TS190P 8 Pin Flatpack (50/Tube) TS190PTR 8 Pin Flatpack (1000/Reel) TS190S 8 Pin Surface Mount (50/Tube) TS190STR 8 Pin Surface Mount (1000/Reel) Pin Configuration TS190 Pinout www.clare.com TS190 1 ...
Page 2
... V RMS - +85 °C - +125 °C - +260 °C - +220 °C Conditions Symbol Min - 10ms I - LPK I =150mA =400V LEAK =5mA, VL=10V =5mA, VL=10V T - OFF 50V; f=1MHz C - OUT =150mA 0 =5mA www.clare.com Typ Max Units - 400 V - 150 mA - 400 mA Ω µ 0. 0 1.2 1 µA Rev. 4 ...
Page 3
... Capacitance Input to Output Input to Output Isolation Rev. 4 Conditions Symbol Min I =10µ CEO =5V, I =0mA CEO =2mA, I =16mA SAT =0.5V CTR 33 CE =0. IF=5mA V 0.9 F =1µ 3750 I/O www.clare.com TS190 Typ Max Units 500 nA 0.3 0.5 V 100 - % 2 100 mA 1.2 1 µ RMS 3 ...
Page 4
... Typical Turn-On vs. Temperature (Load Current = 150mADC) 3.0 2.5 2.0 1.5 1.0 0.5 10mA 20mA 0 100 -40 - 100 Temperature (°C) www.clare.com TS190 Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25° 441.5 450.5 459.5 468.5 477.5 486.5 495.5 Blocking Voltage (V) TS190 Typical Turn-On Time (N=50 Ambient Temperature = 25° ...
Page 5
... Time TS190 Typical Collector Current vs. Forward Current (V = 0.5V 120 (mA) F www.clare.com TS190 Typical Turn-Off vs. LED Forward Current (Load Current = 150mADC) 0.12 0.10 0.08 0.06 0.04 0. LED Forward Current (mA) TS190 Typical I for Switch Dropout vs. Temperature F (Load Current = 150mADC) 3.000 2.500 2.000 1.500 1 ...
Page 6
... PC Board Pattern (Top View) 2.540 ± .127 (.100 ± .005) 8-.800 DIA. (8-.031 DIA.) 7.620 ± .127 6.350 ± ...
Page 7
... Top Cover 11.988 ± .102 .050R TYP. Tape (.472 ± .004) User Direction of Feed www.clare.com TS190 3.987 ± .102 (.157 ± .004) 16.002 ± .305 (.630 ± .012 10.300 (.405) 10.300 ± .102 1.549 ± ...
Page 8
... The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body other applications intended to sup- port or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice ...