Datasheet
HR1S-DMB Safety Relay Module Operation Chart
Non-contact Interlock Switch 1
(S11-S12)
Non-contact Interlock Switch 1
(S11-S13)
Non-contact Interlock Switch 2
(S21-S22)
Non-contact Interlock Switch 2
(S21-S23)
Start Switch
(Y1-Y2)
Transistor Output Y34
(Fault)
Transistor Output Y44
(K1/K2)
Safety Output
13-14/23-24 (NO)
LED Indication
HR1S-DMB
HR1S-DME
Power A1/A2:
Turns on when power circuit is normal.
Turns off when power is interrupted or the electronic fuse blows.
Fault:
Turns on when the HR1S fails (see failure causes on page 694).
K1/K2:
Turns on when K1/K2 relays operate.
Power A1/A2:
Turns on when power circuit is normal.
Turns off when power is interrupted or the electronic fuse blows.
Fault:
Turns on when the HR1S fails (see failure causes on page 694)
K1/K2:
Turns on when K1/K2 relays operate.
S13: NO contact of non-contact interlock switch 1
S12: NC contact of non-contact interlock switch 1
S23: NO contact of non-contact interlock switch 2
S22: NC contact of non-contact interlock switch 2
S33: NO contact of non-contact interlock switch 3
S32: NC contact of non-contact interlock switch 3
S43: NO contact of non-contact interlock switch 4
S42: NC contact of non-contact interlock switch 4
S53: NO contact of non-contact interlock switch 5
S52: NC contact of non-contact interlock switch 5
S63: NO contact of non-contact interlock switch 6
S62: NC contact of non-contact interlock switch 6
IDEC Corporation
Contact Status of
Non-contact
Interlock Switch
2 sec
1175 Elko Drive
< 0.5 sec
ON (0)
OFF (1)
Sunnyvale, CA 94089
©2011 IDEC Corporation. All Rights Reserved. 06/11 PDF only.
< 0.5 sec
Causes of Fault LED Indication
LED2: Fault
800-262-IDEC (4332)
The HR1S-DM terminal block can be
removed and installed as shown, allow-
ing for easy installation and replacement
of modules.
Specifications and other descriptions in this document are subject to change without notice.
Fault Type
Internal Fault
External Fault
External Fault
Synchronization
time excess of
switch con tact
input
Fax: 408-745-5258
Fault Cause
Fault of the internal circuit
Short circuit of the +24V power
supply and input terminal
Short-circuit of the non-contact
interlock switch wiring
Synchronization for the NO
contact and NC con tact of the
non-contact interlock switch
(HS7A) is 0.5 seconds or longer.
Fault of the non-contact
interlock switch (HS7A)
www.IDEC.com/usa
Measures
Replace the safety relay
module.
Remove the short circuit and
reboot.
Correct the wiring of the
non-contact interlock switch
and reboot.
Open and close the door
again.
Replace the non-contact
interlock switch.

Related parts for HR1S-DMB1132P