HR1S-DMB1132P IDEC, HR1S-DMB1132P Datasheet

47T1440

HR1S-DMB1132P

Manufacturer Part Number
HR1S-DMB1132P
Description
47T1440
Manufacturer
IDEC
Datasheet
Safety Control Relay HR1S-DMB/DME
Part Numbers
Specifications
Use a 4A fuse (Type gL) for power fuse protection.
Use a 4A (Type gL) or a 6A fast blow fuse for output fuse protection.
Part Numbers
HR1S-DMB1132
HR1S-DMB1132P
HR1S-DME1132
HR1S-DME1132P
Operating Temperature
Degree of Protection
Rated Power Voltage
Power Consumption
Overcurrent Protection
Control Circuit Voltage
Performance Level (PL)
Safety Category
Safety Integrity Level (SIL)
Response Time
Input Synchronization Time
Overvoltage Category
Pollution Degree
Rated Insulation Voltage
Maximum Input Resistance
Operation Frequency
Rated Current
Wire Size
Weight
1NO-1NC safety input type, such as magnetic coded safety switches
Fault diagnosis function with dual safety circuits.
Internal relay operations can be moni tored with LED Indicator.
Finger-safe protection
22.5 or 45mm wide, 35mm DIN rail mounting
EN ISO 13849-1 PLe, Safety Cat 4 compliant, and EN 62061 SIL 3
UL listed, CSA certified, TÜV NORD approved
Safety Circuit
Auxiliary Contact
Safety
Circuit
Transistor Circuit
Minimum
Applicable Load
AC-15
DC-13
Terminal Style
Integrated terminal block
Removable terminal block
Integrated terminal block
Removable terminal block
–10 to 55°C (no freezing)
Terminal: IP20, Housing: IP40
24V DC (–20 to +20%)
HR1S-DMB: 2.5W maximum (24V DC)
HR1S-DME: 3.5W maximum (24V DC)
Electronic
24V DC
e (EN ISO 13849-1)
4 (EN ISO 13849-1)
3 (EN 62061)
20 ms maximum
500ms max
III
2
300V
100Ω (per input point)
2NO
2NO (transistor PNP)
C300: Ue= 240VAC, Ie=0.75A
Ue= 24V DC, Ie= 1.5A
24V/20 mA
17V/10 mA (initial value)
1200 operations/hour maximum
Output total 12A maximum
0.14 to 2.5 mm2
HR1S-DMB: 180g
HR1S-DME: 250g
Input
2
6
Dimensions (mm)
HR1S-DMB
HR1S-DME
22.5
45
HR1S-DMB( )P
HR1S-DME1132
114
114
HR1S-DMB1132
S11 S12 S13 23
S21 S22 S23 24
A1
A2 Y34 Y44 14
Y1 Y2
13
Terminal Arrangement
HR1S-DMB
HR1S-DMB
HR1S-DME
HR1S-DMB1132P
A1 Y1 Y2 13
S21 S22 S23 24
A2 Y34 Y44 14
S12 S13 23
HR1S-DME1132P
HR1S-DME

Related parts for HR1S-DMB1132P

HR1S-DMB1132P Summary of contents

Page 1

... Use a 4A (Type gL fast blow fuse for output fuse protection. HR1S-DMB( )P Dimensions (mm) HR1S-DMB Input 2 6 22.5 HR1S-DME 45 HR1S-DME HR1S-DMB Terminal Arrangement HR1S-DMB S12 S13 S11 S12 S13 Y34 Y44 14 S21 S22 S23 24 A2 Y34 Y44 14 114 S21 S22 S23 24 HR1S-DMB1132 HR1S-DMB1132P HR1S-DME 114 HR1S-DME1132 HR1S-DME1132P ...