F10-S30R Omron, F10-S30R Datasheet - Page 13

25C4243

F10-S30R

Manufacturer Part Number
F10-S30R
Description
25C4243
Manufacturer
Omron
Datasheet

Specifications of F10-S30R

Sensing Range
90mm To 110mm
Peak Reflow Compatible (260 C)
No
Terminal Type
Wire Leaded
Supply Current Max
150mA
Supply Voltage Max
19.8VDC
Sensor Terminals
Cable
Leaded Process Compatible
No
Rohs Compliant
No
F10
2. Threshold Adjustment/Sample Test (MONITOR Mode)
The Sensor operates in MONITOR mode for threshold level adjustments and desktop sample tests for object discrimination with no signal
output. No external output operation signal or external input signal is accepted in MONITOR mode.
20
(1) Set the mode selector to MON.
Measurement Item: PATT/PLN
Whether measurement is patterned or plain is determined automatically by comparing the deviation level with the background within the
detection range. When teaching is finished, all the level indicators will light for 0.5 s, and the buzzer will sound twice.
Note:
Measurement continues as long as the selector is set to MON.
Pattern Measurement
On the basis of the registered model, the level indicator indicates the degree of conformity of the sensing object.
·
The deviation level will become high if the sensing object has a pat-
tern. If the deviation level is higher than the set level of measurement
item selection, pattern measurement will be performed.
The portion with the highest deviation is
registered as a model.
POINT
Status indicators, F10-C20/C25
Pattern
measurement
A
Do not turn OFF the Sensor before the Sensor is set to MONITOR mode, otherwise the teaching data will be lost.
The set level of measurement item selection is increased
or decreased by pressing the SELECT buttons. Adjust the
level according to the background and deviation. The level
is factory-set between 2 and 3.
If the object has some light-color lines or light-color pat-
terns, pattern measurement may be performed. In this
case, by increasing the set level of measurement item
selection, plain measurement will be performed.
Sensing area
Pattern Measurement
Closer to model
in appearance
PLN
Deviation
The closer to the model in appearance,
the higher the level.
High
Low
DEV
AVE
8
7
6
5
4
3
2
1
Measurement item
selection level
Degree of
conformance
with model
Bank No.
·
Automatic
selection
Status indicator, F10-C30/C35/C50/C55
Not close to model
in appearance
Sensing area
If no sensing object is within the sensing
area or if the sensing object is greatly differ-
ent from the model, the level will be lower.
Plain measurement will be performed if the pattern is close to the edge of
the sensing area.
The deviation and average density in the area enclosed by dotted
lines are registered. The dotted lines are not projected.
The deviation level will be set to low if the sensing object has no
pattern. If the set level of measurement item selection is higher than
the deviation level, plain measurement will be performed.
Teaching Area
The deviation and average density in the teaching area are regis-
tered in the above example. In other words, the sensing area is
restricted so that the pattern close to the edge will not influence
the results of object discrimination.
Press the Switch
Display Item button
(Returns to bank num-
ber display no opera-
tion is performed for 5
seconds.)
Approx. 3.0 mm
(F10-S30R)
Approx. 1.5 mm
(F10-S15R)
Approx. 0.8 mm
(F10-S05R)
Plain Measurement
Teaching is performed in the area enclosed
by dotted lines inside the sensing area. The
pattern close to the edge of the sensing area
is not registered as a model because such a
pattern may not be always located in the
sensing area and accurate measurement
cannot be performed. In this example, the
deviation level in the area enclosed by the
dotted lines is small. Therefore, plain mea-
surement will be performed.
Deviation
High
Low
8
7
6
5
4
3
2
1
Pattern
measurement
Measurement item
selection level
F10