M38517F8FP Renesas Electronics America, M38517F8FP Datasheet - Page 58

no-image

M38517F8FP

Manufacturer Part Number
M38517F8FP
Description
MCU 8-Bit 740 CISC 32KB Flash 5V 42-Pin SSOP
Manufacturer
Renesas Electronics America
Datasheet

Specifications of M38517F8FP

Package
42SSOP
Family Name
740
Maximum Speed
8 MHz
Ram Size
1 KB
Program Memory Size
32 KB
Operating Supply Voltage
5 V
Data Bus Width
8 Bit
Program Memory Type
Flash
Number Of Programmable I/os
34
Interface Type
I2C-BUS
On-chip Adc
5-chx10-bit
Operating Temperature
-20 to 85 °C
Number Of Timers
4
3851 Group
Status Register (SRD)
The status register shows the operating status of the flash
memory and whether erase operations and programs ended suc-
cessfully or in error. It can be read in the following ways:
(1) By reading an arbitrary address from the User ROM area after
(2) By reading an arbitrary address from the User ROM area in the
Also, the status register can be cleared by writing the clear status
register command (50
After reset, the status register is set to “80
Table 17 shows the status register. Each bit in this register is ex-
plained below.
•Sequencer status (SR7)
The sequencer status indicates the operating status of the flash
memory. This bit is set to “0” (busy) during write or erase operation
and is set to “1” when these operations ends.
After power-on, the sequencer status is set to “1” (ready).
Table 17 Definition of each bit in status register (SRD)
Rev.1.01
writing the read status register command (70
period from when the program starts or erase operation starts
to when the read array command (FF
SR7 (bit7)
SR6 (bit6)
SR5 (bit5)
SR4 (bit4)
SR3 (bit3)
SR2 (bit2)
SR1 (bit1)
SR0 (bit0)
Symbol
Oct 15, 2003
(Built-in 24 KB or more ROM)
16
).
page 56 of 89
Sequencer status
Reserved
Erase status
Program status
Reserved
Reserved
Reserved
Reserved
Status name
16
16
) is input.
”.
16
)
•Erase status (SR5)
The erase status indicates the operating status of erase operation.
If an erase error occurs, it is set to “1”. When the erase status is
cleared, it is set to “0”.
•Program status (SR4)
The program status indicates the operating status of write opera-
tion. When a write error occurs, it is set to “1”.
The program status is set to “0” when it is cleared.
If “1” is written for any of the SR5 and SR4 bits, the program,
erase all blocks, and block erase commands are not accepted.
Before executing these commands, execute the clear status regis-
ter command (50
Also, if any commands are not correct, both SR5 and SR4 are set
to “1”.
Terminated in error
Terminated in error
Ready
“1”
-
-
-
-
-
16
) and clear the status register.
Definition
Terminated normally
Terminated normally
“0”
Busy
-
-
-
-
-

Related parts for M38517F8FP