AM28F010-90JI Spansion Inc., AM28F010-90JI Datasheet - Page 18

no-image

AM28F010-90JI

Manufacturer Part Number
AM28F010-90JI
Description
Manufacturer
Spansion Inc.
Datasheet

Specifications of AM28F010-90JI

Cell Type
NOR
Density
1Mb
Access Time (max)
90ns
Interface Type
Parallel
Boot Type
Not Required
Address Bus
17b
Operating Supply Voltage (typ)
5V
Operating Temp Range
-40C to 85C
Package Type
PLCC
Program/erase Volt (typ)
11.4 to 12.6V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
4.5V
Operating Supply Voltage (max)
5.5V
Word Size
8b
Number Of Words
128K
Supply Current
30mA
Mounting
Surface Mount
Pin Count
32
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AM28F010-90JI
Manufacturer:
LAI
Quantity:
5 555
ANALYSIS OF PROGRAM TIMING WAVEFORMS
Program Setup/Program
Two-cycle write commands are required for program
operations (section A and B). The first program com-
mand (40h) is a Setup command and does not affect
the array data (section A). The second program com-
mand latches address and data required for program-
ming on the falling and rising edge of WE# respectively
(section B). The rising edge of this WE# pulse (section
B) also initiates the programming pulse. The device is
programmed on a byte by byte basis either sequentially
or randomly.
The program pulse occurs in section C.
18
Bus Cycle
Command
Function
Addresses
Section
WE
OE
Data
CE
V
V
CC
PP
#
#
#
Program
Setup
Write
40h
A
Figure 4. AC Waveforms for Programming Operations
Program Data
Address and
A
Command
Address,
Program
Program
Latch
Write
Data
20h
B
B
Time-out
Program
(10 s)
N/A
Data
C
In
Am28F010
C
Time-Out
A software timing routine (10 µs duration) must be initi-
ated on the rising edge of the WE# pulse of section B.
Note: An integrated stop timer prevents any possibility
of overprogramming by limiting each time-out period of
10 µs.
Program-Verify
Upon completion of the program timing routine, the mi-
croprocessor must write the program-verify command
(C0h). This command terminates the programming op-
eration on the rising edge of the WE# pulse (section D).
The program-verify command also stages the device
for data verification (section F). Another software timing
Program)
Program
(Stops
Verify
Write
C0h
D
A0h
D
Transition
Time-out
(6 s)
E
N/A
E
Verification
F
Compare
Program
Read
Data
Data
F
Out
G
Programming
Proceed per
Algorithm
Standby
N/A
11559G-9
G