Datasheet
Complete with IP20 finger-safe contact blocks
Ensure safety and save wiring time
• The locking lever removable contact block features spring-up
• Self-cleaning rolling action contacts have a raked contact sur-
• Degree of protection: IP65
• A wide range of operating voltages for worldwide application
• UL, CSA approved, and EN compliant
Contact Ratings
Characteristics
• Contact Ratings by Utilization Category
Note: The operational current represents the classification by making and breaking currents (IEC 60947-5-1).
Minimum applicable load: 3V AC/DC, 5 mA (applicable range may vary with operating conditions and load types)
HW-G Contact Block
4
UL
CSA
EN
Pushbuttons
Illuminated Pushbuttons
Selector Switches
Illuminated Selector Switches
Pushbutton Selectors
Operational Voltage
Operational
Current
screw terminals.
face.
For the control units listed below, the rated current (load switching current) is reduced to a half of the rated operational current of the con-
tact block. The rated insulation voltage (600V) and the rated thermal current (10A) remain unchanged.
• 3-position selector switches which contain J or S following 3 in the Type No. and which have cam code J or S. Example: HW1S-3JT21N1
• All 4-position and 5-position selector switches
• All mono-lever switches
• All pushbutton selectors
• Contact Block Types
Type No.
Contact
Housing
Push Rod
Specifications and Ratings
Safety Standards
ø22
EN60947-1
EN60947-5-1
• Finger-safe terminal
Compliant to VDE 0106 Part 100
AC
50/60 Hz
DC
HW-G10
Green
HW
• Push rod
Blue
NO
Color-coded for different contacts
AC-12 Control of resistive loads and solid state loads
AC-15 Control of electromagnetic loads (> 72 VA)
DC-12 Control of resistive loads and solid state loads
DC-13 Control of electromagnets
UL Listing
File No. E68961
File No. LR92374
• Snap-fit latch
Purple red
HW-G01
Series
Red
NC
File No. or Organization
TÜV Rheinland R9551089
NO (early make)
HW-G10R
Control Units
Contact Block
Rated Insulation Voltage
Rated Continuous Current
Contact Ratings by Utilization Category
IEC 60947-5-1
Black
Blue
• Double-break rolling action silver
contacts with raked surface
• Housing in different colors
• Insertion from two directions
• Ring or fork connectors can
• Spring-up terminal is ready for wiring.
for NO and NC contact.
also be used.
Screw is held captive.
NC (late break)
HW-G01R
Purple red
White
24V
10A
10A
8A
4A
48V
4A
2A
Transformer Unit
• Finger-safe spring-up terminal
• Wires can be inserted from
50V
10A
7A
three directions.
Type HW-G (HW series)
DC-13 (P600)
AC-15 (A600)
110V
2.2A
1.1A
10A
5A
600V
10A
220V
1.1A
0.6A
6A
3A
440V
2A
1A