SI2457-D-FT Silicon Laboratories Inc, SI2457-D-FT Datasheet - Page 75

no-image

SI2457-D-FT

Manufacturer Part Number
SI2457-D-FT
Description
IC ISOMODEM SYSTEM-SIDE 24TSSOP
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of SI2457-D-FT

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
+VRA = n
+VRID = n
+VRN = n
+VRX
+VSD =
<sds>, <sdi>
Command
Table 39. Basic AT Command Set (Continued)
Ringing Tone Goes Away Timer.
The ISOmodem only uses this command in call origination trans-
actions. This command sets the amount of time in 0.1 second units
the ISOmodem shall wait between Ringing Tone before it can
assume that the remote modem has gone off-hook. Default time
is five seconds.
Repeat Caller ID.
n
0
call in formatted form.
1
call in unformatted form.
Ringing Tone Never Appeared Timer.
This command sets the amount of time in seconds the ISOmodem
will wait looking for Ringing Tone. If the ISOmodem does not
detect Ringing Tone in this time period, the ISOmodem shall
assume that the remote station has gone off-hook and return an
OK result code. Default time is 0 seconds.
Receive Voice Stream.
Enable DTE receive of voice stream. The DCE will return a CON-
NECT response followed by the voice stream as defined by the
+VSM command. The DTE can issue a <DLE><!> or
<DLE><ESC> sequence to terminate the receive stream. The
DCE will return a <DLE><ETX> followed by an OK response for
<DLE><!> and <DLE><ESC> followed by an OK response for
<DLE><ESC>. The DCE can be configured to terminate the
stream using the DTE/DCE Inactivity Timer, which is configured
using the +VIT command. The DTE will need to process any
<DLE> shielded events present in the data stream. Any
<DLE><DLE> sequences can be preserved to allow less overhead
during playback of the stream with the +VTX command.
Silence Detection.
<sds>
127
128
129
<sdi> sets the length of a time interval in 0.1 second units, which
must contain no or little activity, before the ISOmodem will report
(QUIET) (<DLE><q>). Default is five seconds.
els considered to be silence].
Description
Display Caller ID information of the last incoming
Display Caller ID information of the last incoming
Noise level sensitivity
Less aggressive [more sensitive, lower noise lev-
els considered to be silence].
Nominal level of sensitivity.
More aggressive [less sensitive, higher noise lev-
Rev. 1.3
Action
AN93
75

Related parts for SI2457-D-FT