5.7.4. U31–U33 (Ringback Cadence Registers)
U31, U32, and U33 set the ringback cadence minimum total time (RMTT), ringback cadence delta time (RDLT),
and ringback cadence minimum on time (RMOT) (see Table 51). Country-specific settings for ringback cadences
are specified as a range for “on” time (minimum “on” and maximum “on”) and a range for “off” time (minimum “off”
and maximum “off”). The three values represented by RMTT, RDLT, and RMOT fully specify these ranges. RMTT,
minimum total time, is equal to the minimum “on” time plus the minimum “off” time. RDLT (allowable delta) is equal
to the maximum total time (maximum “on” time plus the maximum “off” time) minus the minimum total time (RMTT).
RMOT is the minimum “on” time. The values stored in the registers are the hexadecimal representation of the times
in seconds multiplied by 7200. Default values meet FCC requirements.
5.7.5. U34–U35 (Dial Tone Timing Register)
U34 determines the period of time the modem attempts to detect a dial tone. U35 sets the time within this window
that the dial tone must be present in order to return a valid dial tone detection. The value stored in U35 is the
hexadecimal representation of the time in seconds multiplied by 7200.
The value in U34 is the hexadecimal representation of the time in seconds multiplied by 1000. The time window
represented in U34 must be larger than the dial tone present time represented in register U35 (see Table 52).
5.7.6. U37–U45 (Pulse Dial Registers)
Registers U37–U40 set the number of pulses to dial digits 0 through 9, respectively (see Table 53). The values are
entered in hexadecimal format with digit 0 having a default setting of 0x000A (10 decimal) pulses, digit 1 having a
default setting of one pulse, digit 2 having a default setting of two pulses, etc. This pulse arrangement is used
throughout most of the world. There are, however, two exceptions—New Zealand and Sweden. New Zealand
requires 10 pulses for 0, nine pulses for 1, eight pulses for 2, etc. Sweden, on the other hand, requires one pulse
for 0, two pulses for 1, etc. Complete information is provided in "6.2. Country-Dependent Setup" on page 133.
U42, U43, and U45 set the pulse dial break time (PDBT), make time (PDMT), and interdigit delay time (PDIT),
respectively. The values are entered in hexadecimal format and represent milliseconds. The default values meet
FCC requirements. The default dialing speed is 10 pps. See "6.2. Country-Dependent Setup" on page 133 for
Japanese 20 pps dialing configuration.
Register
Register
U31
U32
U33
U34
U35
RMOT
DTWD
DMOT
RMTT
Name
Name
RDLT
Ringback cadence minimum total time in seconds multiplied by 7200.
Ringback cadence delta in seconds multiplied by 7200.
Ringback cadence minimum on time in seconds multiplied by 7200.
Window to look for dial tone in seconds multiplied by 1000
Minimum dial tone on time in seconds multiplied by 7200
Table 51. Ringback Cadence Registers
Table 52. Dial Tone Timing Register
Rev. 1.3
Description
Description
AN93
Default
0xEF10
Default
0x1B58
0x2D00
0x4650
0x1200
101