M29W128GL70N6E Micron Technology Inc, M29W128GL70N6E Datasheet - Page 31

no-image

M29W128GL70N6E

Manufacturer Part Number
M29W128GL70N6E
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of M29W128GL70N6E

Cell Type
NOR
Density
128Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Not Required
Address Bus
24/23Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
16M/8M
Supply Current
10mA
Mounting
Surface Mount
Pin Count
56
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W128GL70N6E
Manufacturer:
MICRON
Quantity:
11 200
Part Number:
M29W128GL70N6E
Manufacturer:
LATTICE
Quantity:
198
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
STM
Quantity:
1 000
Part Number:
M29W128GL70N6E
Manufacturer:
MICRON
Quantity:
20 000
Company:
Part Number:
M29W128GL70N6E
Quantity:
920
Company:
Part Number:
M29W128GL70N6E
Quantity:
900
M29W128GH, M29W128GL
Command interface
6.1.10
Program command
The Program command can be used to program a value to one address in the memory
array at a time. The command requires four bus write operations, the final write operation
latches the address and data in the internal state machine and starts the program/erase
controller.
Programming can be suspended and then resumed by issuing a Program Suspend
command and a Program Resume command, respectively (see
Section 6.1.8: Program
and
Suspend command
Section 6.1.9: Program Resume
command).
If the address falls in a protected block then the program command is ignored, the data
remains unchanged. The status register is never read and no error condition is given.
After programming has started, bus read operations output the status register content. See
and
Figure 17: Write enable controlled program waveforms (8-bit mode)
Figure 18: Write
for more details. Typical program times
enable controlled program waveforms (16-bit mode)
are given in
Table 17: Program, erase times and program, erase endurance
cycles.
After the program operation has completed the memory will return to the read mode, unless
an error has occurred. When an error occurs, bus read operations to the memory continue
to output the status register. A Read/Reset command must be issued to reset the error
condition and return to read mode.
One of the erase commands must be used to set all the bits in a block or in the whole
memory from ’0’ to ’1’.
The program operation is aborted by performing a reset or powering-down the device. In
this case data integrity cannot be ensured, and it is recommended to reprogram the word or
byte aborted.
31/94