D3403 TE Connectivity, D3403 Datasheet

no-image

D3403

Manufacturer Part Number
D3403
Description
RELAY TELECOM DPDT 2A 5VDC TH
Manufacturer
TE Connectivity
Series
FT2, AXICOMr
Datasheets

Specifications of D3403

Relay Type
Telecom
Contact Form
DPDT (2 Form C)
Contact Rating (current)
2A
Switching Voltage
250VAC, 220VDC - Max
Coil Type
Non Latching
Coil Current
60mA
Coil Voltage
5VDC
Turn On Voltage (max)
3.75 VDC
Turn Off Voltage (min)
0.5 VDC
Features
-
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Material
Palladium (Pd), Ruthenium (Ru), Gold (Au)
Operate Time
5ms
Release Time
5ms
Coil Power
300 mW
Coil Resistance
83.3 Ohms
Operating Temperature
-55°C ~ 85°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
1462035-3
n
n
n
n
n
n
Typical applications
Communications equipment, linecard application – analog, ISDN, xDSL,
PABX, voice over IP, office and business equipment, measurement and
control equipment, consumer electronics, set top boxes, HiFi, medical
equipment
09-2010, Rev. 0910
www.tycoelectronics.com
© 2010 Tyco Electronics Ltd.
Approvals
cULus 508 File No. E 111441
Technical data of approved types on request
Contact Data
Contact arrangement
Max. switching voltage
Rated current
Limiting continuous current
Switching power
Contact material
Contact style
Min. recommended contact load
Initial contact resistance
Thermoelectric potential
Operate time
Release time
Bounce time max.
Electrical endurance
Contact ratings, UL contact rating
Mechanical endurance
Telecom/signal relay (dry circuit, test access, ringing)
Slim line 15x7.5mm (.59x.295”)
Switching current 2A
2 form C bifurcated contacts (2 CO)
High sensitive 24V and 48V coil versions
Meets Telcordia GR 1089, FCC Part 68 and ITU-T K20, ≥ 2500V
between coil and contacts
without diode in parallel
with diode in parallel
at contact application 0
(≤ 30mV/≤10mA)
cable load open end
resistive, 24V / 1.25A - 30W
resistive, 30VDC / 2A - 60W
resistive, 125VDC / 0.24A - 30W
Max. DC load breaking capacity
Signal Relays
FT2/FU2 Relay
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
250VAC, 0.25A, 62.5VA
min. 2.5x10
min. 2.0x10
125VAC, 0.5A, 62.5VA
min. 1x10
min. 1x10
min. 1x10
220VDC, 0.24A, 60W
125VDC, 0.24A, 30W
typ. 3ms, max. 5ms
typ. 2ms, max. 5ms
typ. 4ms, max. 5ms
typ. 1ms, max. 5ms
100x10
DC current [A]
PdRu, Au covered
220VDC, 250VAC
30VDC, 2A, 60W
2 Form C (CO)
twin contacts
60W, 62.5VA
100µV/1µA
<50mΩ
<10µV
6
2A
2A
5
5
5
operations
6
6
operations
operations
operations
operations
operations
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.tycoelectronics.com/definitions
Coil Data
Magnetic system
Coil voltage range
Max. coil temperature
Thermal resistance
Coil versions, monostable
Standard version, monostable
High dielectric version, monostable
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
96
97
Coil
code
21
29
22
23
24
25
26
27
28
91
93
Coil Operating Range
2.6
2.4
2.2
1.8
1.6
1.4
1.2
0.8
0.6
0.4
0.2
2.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
2
1
0
-60 -50 -40 -30 -20 -10 0
voltage
Rated
VDC
U
U
4.5
12
24
48
12
24
3
4
5
6
9
3
5
nom.
nom.
nominal coil voltage
nominal coil voltage
Operate
voltage
18.00
36.00
18.00
VDC
2.25
3.00
3.38
3.75
4.50
6.75
9.00
2.25
3.75
9.00
Ambient Temperature [°C]
10 20 30 40 50 60 70 80 90 10
Limiting
voltage
10.10
11.20
13.50
20.30
27.00
47.50
95.00
11.20
27.00
47.50
VDC
6.80
9.00
6.80
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
Telecom-, Signal and RF Relays
FT2/FU2 Relay
monostable, non polarized
Release
voltage
VDC
4.80
0.30
0.50
1.20
2.40
0.30
0.40
0.45
0.50
0.60
0.90
1.20
2.40
3 to 48VDC
U
U
U
U
U
<125K/W
max.
max.
max.
op. min.
rel. min.
150°C
0
U
U
U
200 mW coil
240 mW coil
Z
max.
max.
max.
at 0 A
at 2 x 1 A
at 2 x 2 A
300 mW coil
11
0
resistance
Ω±10%
at 0 A
at 2 x 1 A
at 2 x 2 A
12
0
2400
9600
2400
101
125
180
405
720
125
720
U
U
Coil
45
80
45
13
op. min.
0
rel. min.
14
0
Axicom
Rated coil
power
mW
200
200
200
200
200
200
200
240
240
200
200
200
240
U
Umax. =
Uop. min. =
Urel. min. =
nom
1
= Nom

Related parts for D3403

D3403 Summary of contents

Page 1

... Telecom-, Signal and RF Relays 48 36.00 95.00 4.80 FT2/FU2 Relay 3 2.25 6.80 0.30 5 3.75 11.20 0.50 12 9.00 27.00 1.20 24 18.00 47.50 2.40 2.6 200 mW coil 240 mW coil 2 ...

Page 2

... Coil Operating Range Signal Relays 2.6 FT2/FU2 Relay 2.4 2.2 2 1.8 Coil Data (continued) 1.6 1.4 Coil versions, monostable 1.2 Coil Rated Operate Limiting U nominal coil voltage code voltage 1 voltage voltage nom. VDC VDC VDC 0.8 High dielectric Australia version, monostable ...

Page 3

... Signal Relays FT2/FU2 Relay Dimensions THT version 15.0±0.05 15.0±0.05 7.5±0.05 7.5±0.05 7.5±0.05 0.5 0.5 5.08 5.08 5.08 Processing Recommended soldering conditions Vapour phase soldering 20 to 40s 240°C 180°C 130°C external preheating 100°C Recommended refl ...

Page 4

... Signal Relays FT2/FU2 Relay Product code structure Type D34 Signal Relays FT2 (THT) D35 Signal Relays FU2 (SMT) 2 form Coil Coil code: please refer to coil versions table Performance and coil type 2x Standard version, monostable 9x High dielectric version, monostable 7x High dielectric, Australia version, monostable (SMT version only) ...

Related keywords