M29W320ET70ZE6E Micron Technology Inc, M29W320ET70ZE6E Datasheet - Page 26

no-image

M29W320ET70ZE6E

Manufacturer Part Number
M29W320ET70ZE6E
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of M29W320ET70ZE6E

Cell Type
NOR
Density
32Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Top
Address Bus
22/21Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TFBGA
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
4M/2M
Supply Current
10mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W320ET70ZE6E
Manufacturer:
SIEMENS
Quantity:
2
Part Number:
M29W320ET70ZE6E
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
M29W320ET70ZE6E
Manufacturer:
ST
0
Part Number:
M29W320ET70ZE6E
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
M29W320ET70ZE6E
Quantity:
76 000
4.12
4.13
4.14
4.15
26/65
During Erase Suspend it is possible to Read and Program cells in blocks that are not being
erased; both Read and Program operations behave as normal on these blocks. If any
attempt is made to program in a protected block or in the suspended block then the Program
command is ignored and the data remains unchanged. The Status register is not read and
no error condition is given. Reading from blocks that are being erased will output the Status
register.
It is also possible to issue the Auto Select, Read CFI Query and Unlock Bypass commands
during an Erase Suspend. The Read/Reset command must be issued to return the device to
Read Array mode before the Resume command will be accepted.
During Erase Suspend a Bus Read operation to the Extended Block will output the
Extended Block data.
Erase Resume command
The Erase Resume command must be used to restart the Program/Erase Controller after an
Erase Suspend. The device must be in Read Array mode before the Resume command will
be accepted. An erase can be suspended and resumed more than once.
Enter Extended Block command
The M29W320E has an extra 64Kbyte block (Extended Block) that can only be accessed
using the Enter Extended Block command. Three Bus write cycles are required to issue the
Extended Block command. Once the command has been issued the device enters
Extended Block mode where all Bus Read or Program operations to the Boot Block
addresses access the Extended Block. The Extended Block (with the same address as the
boot block) cannot be erased, and can be treated as one-time programmable (OTP)
memory. In Extended Block mode the Boot Blocks are not accessible.
To exit from the Extended Block mode the Exit Extended Block command must be issued.
The Extended Block can be protected, however once protected the protection cannot be
undone.
Exit Extended Block command
The Exit Extended Block command is used to exit from the Extended Block mode and return
the device to Read mode. Four Bus Write operations are required to issue the command.
Block Protect and Chip Unprotect commands
Groups of blocks can be protected against accidental Program or Erase. The Protection
groups are shown in
Addresses. The whole chip can be unprotected to allow the data inside the blocks to be
changed.
Block Protect and Chip Unprotect operations are described in
Appendix A: Block
Addresses,
Table 21
and
Appendix D: Block
Table
22, Block
Protection.