CKSR 6-NP LEM USA Inc, CKSR 6-NP Datasheet

SENSOR CURRENT 6A 5V MOD

CKSR 6-NP

Manufacturer Part Number
CKSR 6-NP
Description
SENSOR CURRENT 6A 5V MOD
Manufacturer
LEM USA Inc
Series
CKSRr
Datasheet

Specifications of CKSR 6-NP

Current - Sensing
6A
Accuracy
±0.8%
Sensitivity
104.2mV/A
Current - Supply
-
Sensor Type
Flux Gate
Voltage - Supply
4.75 V ~ 5.25 V
Output
0 ~ 5 VDC
Frequency
300kHz
Response Time
300ns
Polarization
Bidirectional
Operating Temperature
-40°C ~ 105°C
Package / Case
Module
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
398-1095-5
CAS / CASR / CKSR series Current Transducers
Insulated Highly Accurate Measurements
from 1.5 to 50 A
RMS

Related parts for CKSR 6-NP

CKSR 6-NP Summary of contents

Page 1

... CAS / CASR / CKSR series Current Transducers Insulated Highly Accurate Measurements from 1 RMS ...

Page 2

... This is the human nature and allows the progress of technology. With the LTS / LTSR current transducers using the Closed Loop Hall effect technology coupled with a dedicated ASIC (Application Specific Integrated Circuit) specially designed for these products, we thought we had reached the optimal performance, but this was without taking the eternal human nature into account ...

Page 3

... Loop sensitivity”. Given an equal electronic circuit, the zero output of a current transducer (traditionally called “offset” in analogy to operational amplifiers) will be less influenced by changes Fig. 1. Closed Loop Fluxgate Technology used for the CAS / CASR / CKSR current transducers Magnetic Core I P ...

Page 4

... Moreover, the same compact design is used to cover the complete current range from Transducers dimensions Fig. 2. CAS / CASR / CKSR smaller compared to the LTS / LTSR models 4 standard models ( and 50 A models) for in a very each series CAS, CASR and CKSR ...

Page 5

... ± ± ± Output voltage CASR 25-NP is used with internal reference. Fig. 4a. Different nominal current ranges possible according to the primary current circuit configuration (as example: CAS or CASR 25-NP) Variant 1 Variant 2 Expected for: Expected for (85 A max 8.33 A (28.33 A max) PN ...

Page 6

... PN 1 ± ± ± ± 1.5 * Output voltage CKSR 6-NP is used with internal reference. Fig. 5. Different nominal current ranges possible according to the primary current circuit configuration – CKSR 6-NP model as example allows nominal current measurement from 1 Ref IN/OUT Creepage secondary primary ...

Page 7

... Fig. 6: Differential current measurement ( – I2), many possibilities With that value, and PD2 and CTI of 600 V (group I), this leads to a possible rated insulation voltage of 800 V ...

Page 8

... The Ref pin has two basic functional modes: The first mode is called “Ref out mode”. In this mode, for a primary current the output voltage is equal to the 8 voltage at the Ref pin + an offset depending to the model to cover used (between the voltage output and the Ref pin). ...

Page 9

... Offset drift (25°C .. 85°C) (max) Sensitivity drift (25°C .. 85°C) (max) Linearity (max) Accuracy at +25 °C (max) Accuracy at +85 °C (max) Offset (max) Operating temperature range Nominal current Measuring range Response time Bandwidth (±1 dB) Output voltage noise, 100 Hz..10 kHz (typ.) Output ...

Page 10

... PN time, at Fig. 8. CASR 50-NP Response time to a current step Fig. 10a. Typical common mode behaviour (1200 V of voltage variation applied with /µs) Fig. 10b. CASR 50-NP ; Typical common mode behaviour ; V (1200 V of voltage variation applied with dV/ kV/µ ...

Page 11

... For example, a voltage change of 10 kV/µs in combination with coupling capacity generates a parasitic output current of 100 mA. For the CAS 25-NP for example, this would represent seven times the nominal current. Fig. 10a shows the behaviour at a voltage change of 20 kV/µs and an applied voltage of + 600 V (total voltage variation of 1200 V from – ...

Page 12

... The leakage current from the Ref pin (source) must be lower than 350 µA when the load is connected to a voltage > 2.5 V. • The leakage current from the Ref pin (sink) must be lower than 4.4 µA when the load is connected to a voltage < 2.5 V. ...

Page 13

The following graphs show how the measuring range of each transducer version depends on the external reference voltage value V : REF (V Upper limit -. 44.4 P REF REF (V Lower limit -.6 ...

Page 14

Primary conductor resistance At 25 °C, one primary conductor has a resistance of 0.72 mΩ typ °C, one primary conductor has a resistance of 0.88 mΩ typ. Number of primary Connection conductor ...

Page 15

... CKSR models for higher insulation • Measures the same given performance current as small as 1.5 A with the CKSR 6-NP model RMS • Resistant in rough environmental conditions of use such as high humidity combined with high temperature These advantages are suited for high performance drives, ...

Page 16

Absolute maximum ratings Parameter Supply voltage Primary conductor temperature ESD rating, Human Body Model (HBM) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum ratings for extended periods may degrade reliability. Isolation characteristics Parameter RMS voltage for ...

Page 17

... Electrical data CAS / CASR / CKSR 6- 25° turn kΩ, (internal reference for CASR & CKSR models) unless otherwise noted Parameter Primary nominal current rms Primary current, measuring range Number of primary turns Supply voltage Current consumption Reference voltage @ External reference voltage Output voltage ...

Page 18

... REF Temperature coefficient OUT P Theoretical sensitivity Sensitivity error Temperature coefficient of G Linearity error Magnetic offset current ( referred to primary Output current noise (spectral density) rms 100 Hz .. 100 kHz referred to primary Peak-peak output ripple at oscillator frequency f = 450 kHz (typ.) Reaction time @ Response time @ Frequency bandwidth (± ...

Page 19

... REF Temperature coefficient OUT P Theoretical sensitivity Sensitivity error Temperature coefficient of G Linearity error Magnetic offset current ( referred to primary Output current noise (spectral density) rms 100 Hz .. 100 kHz referred to primary Peak-peak output ripple at oscillator frequency f = 450 kHz (typ.) Reaction time @ Response time @ Frequency bandwidth (± ...

Page 20

... REF Temperature coefficient OUT P Theoretical sensitivity Sensitivity error Temperature coefficient of G Linearity error Magnetic offset current ( referred to primary Output current noise (spectral density) rms 100 Hz .. 100 kHz referred to primary Peak-peak output ripple at oscillator frequency f = 450 kHz (typ.) Reaction time @ Response time @ Frequency bandwidth (± ...

Page 21

PCB footprints CAS Series PCB footprint Pad design according to IPC 2222, IPC 2221 Dimensions in mm 0.034 inches Assembly on PCB Recommended PCB hole diameter 1.3 mm for primary pin 0.8 mm for secondary ...

Page 22

Dimensions (in mm. General linear tolerance ± 0.25 mm) CAS Series Connection Side view CASR Series Connection Side view CKSR Series Connection Side view 22 Bottom view Front view Bottom view Front view Bottom view Front view ...

Page 23

... We design and manufacture high quality and highly reliable products for our customers all over the world. We have delivered several million current and voltage transducers since 172 and most of them are still being used today for traction vehicles, industrial motor drives, UPS systems and many other applications requiring high quality standards. ...

Page 24

Austria Finland LEM Components ETRA Electronics Oy Am Concorde Park 2/F Lampputie 2 A-2320 Schwechat FI-00740 Helsinki Tel. +43 1 903 Tel. +358 207 65 160 Fax +43 1 903 Fax +358 207 65 ...